Stoklu siparişleriniz aynı gün kargoda!

Digital Salinity Refractometer PR-100SA | Atago

Fiyat Sorunuz

ATAGO PR-100SA digital refractometer for rapid and practical measurement of seawater and salt solution salinity in ‰. Ideal for aquaculture, marine aquarium, and water analysis applications.

  • Wide salinity measurement range: 0-100‰
  • 1‰ resolution, ±2‰ accuracy
  • Automatic temperature compensation: 5-40°C
  • Portable operation with 006P (9V) battery
  • Calibration certificate included
  • Compact design: 17×9×4 cm, 270g

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The ATAGO PR-100SA (Salinity) is a digital handheld refractometer designed to measure salinity concentration in liquid samples expressed in per mil (‰). With its wide measurement range of 0-100‰, it can be applied to diverse samples from fresh water to hypersaline solutions. Requiring only a few drops of sample, it delivers results within seconds with a single button press.

The instrument is a practical field and laboratory tool for aquaculture facilities, marine aquarium operators, seawater analysis laboratories, and water treatment/desalination plants. Automatic temperature compensation between 5-40°C ensures reliable readings across varying environmental conditions. Supplied with calibration certificate, it is the preferred choice for applications requiring traceability.

Its simple operation and minimal sample requirement save time during field work and routine quality control processes.

Technical Specifications

Model PR-100SA (Salinity)
Catalog Number 3488
Measurement Parameter Salinity (‰)
Measurement Range 0 – 100‰
Resolution 1‰
Accuracy ±2‰
Temperature Compensation 5 – 40°C
Power Source 006P (9V) Battery
Dimensions / Weight 17×9×4 cm, 270g
Calibration Certificate Included
IP Rating None

Applications

  • Seawater salinity measurement
  • Salinity control in aquaculture and fish farms
  • Marine aquarium water management
  • Analysis in water treatment and desalination facilities

Frequently Asked Questions

At what temperature range does the PR-100SA provide accurate measurement?
The instrument delivers accurate results with automatic temperature compensation between 5-40°C.
How much sample is required for measurement?
Only a few drops of liquid sample are needed; measurement is performed by applying the sample to the prism surface.
Does the instrument come calibrated?
Yes, a calibration certificate is supplied with the product.