Stoklu siparişleriniz aynı gün kargoda!

ChemoMetec Solution 7 (JC-1) 1ml – Mitochondrial Membrane Potential Reagent

Fiyat Sorunuz

JC-1 fluorescent dye reagent for NC-3000 cell analysis platforms. Used in conjunction with Solution 8 for mitochondrial membrane potential and apoptosis detection assays. Supplied as 1 ml volume.

  • Contains JC-1 fluorescent dye
  • Designed for Mitochondrial Membrane Potential Testing with NC-3000
  • Requires use in combination with Solution 8
  • Enables apoptosis detection via green (~529 nm) to red (~590 nm) fluorescence shift
  • 1 ml volume, ChemoMetec original reagent

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

ChemoMetec Solution 7 is a fluorescent reagent containing JC-1 dye, specifically formulated for use with the NC-3000 cell imaging analysis platform for Mitochondrial Membrane Potential Testing. It provides a practical solution for laboratory workflows focused on cell biology and apoptosis research.

JC-1 dye penetrates mitochondria in healthy (non-apoptotic) cells, causing a characteristic fluorescence shift from green (~529 nm) to red (~590 nm). When JC-1 accumulation in mitochondria decreases, cells emit green fluorescence, indicating progression into apoptosis. This mechanism enables rapid and visual assessment of mitochondrial health status across cell populations.

Solution 7 must be used in combination with Solution 8 for optimal assay performance. The 1 ml volume is suitable for small to medium-scale experimental series. Engineered for full compatibility with ChemoMetec's NC-3000 image-based cell analysis system.

Technical Specifications

Manufacturer ChemoMetec
Active Component JC-1 fluorescent dye
Volume 1 ml
Application NC-3000 Mitochondrial Membrane Potential Test
Companion Reagent Solution 8
Fluorescence Emission (healthy cells) ~590 nm (red)
Fluorescence Emission (apoptotic cells) ~529 nm (green)

Applications

  • Apoptosis detection in cell biology laboratories
  • Mitochondrial membrane potential assessment
  • Drug screening and cytotoxicity studies for NC-3000 users

Frequently Asked Questions

Can Solution 7 be used independently?
No, Solution 7 must be used in conjunction with Solution 8 to perform the complete Mitochondrial Membrane Potential Test.
Which instrument is Solution 7 compatible with?
Solution 7 is formulated specifically for use with the ChemoMetec NC-3000 cell analysis platform.
What parameter does JC-1 dye measure?
JC-1 measures mitochondrial membrane potential status and indicates apoptotic state through characteristic changes in fluorescence color emission.