Stoklu siparişleriniz aynı gün kargoda!

SENSIColumn IAC Immunoaffinity Columns for Deoxynivalenol and Zearalenone

Fiyat Sorunuz

Specialized SENSIColumn IAC immunoaffinity columns designed for rapid extraction and purification of Deoxynivalenol (DON) and Zearalenone (ZON) in food and feed analysis. 50 columns per package, 3 ml volume each, compatible with LC-MS/MS and HPLC instrumentation.

  • 50 prepacked columns (3 ml each) per package
  • Working range: DON and ZON 5–500 ng per IAC
  • Zero contamination: <5 ng (HPLC method LOD)
  • Recovery rates >85% for both analytes
  • Maximum column capacity: 1.8 µg DON, 2.7 µg ZON
  • Cross-reactive with DON, NIV, acetyl-DON isomers, ZON, and zearalanol congeners at 100%
  • LC-MS/MS and HPLC compatible

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

SENSIColumn IAC immunoaffinity columns offer high-specificity cleanup and concentration for mycotoxin analysis. Each package contains 50 prepacked 3 ml columns engineered specifically for DON and ZON isolation from complex food and feed matrices. The columns integrate seamlessly with LC-MS/MS and HPLC workflows, delivering reproducible recovery rates exceeding 85% and minimal baseline contamination. Ideal for regulatory compliance testing and research laboratories requiring rapid mycotoxin screening.

Technical Specifications

Package Contents 50 columns/package, 3 ml each
Working Range (DON) 5–500 ng per IAC
Working Range (ZON) 5–500 ng per IAC
Column Contamination Limit (DON) <5 ng (HPLC method LOD)
Column Contamination Limit (ZON) <5 ng (HPLC method LOD)
Recovery Rate (DON) >85%
Recovery Rate (ZON) >85%
Maximum Column Capacity (DON) 1.8 µg
Maximum Column Capacity (ZON) 2.7 µg
Format Prepacked immunoaffinity columns
Volume per Column 3 ml
Analytical Compatibility LC-MS/MS, HPLC

Applications

  • Deoxynivalenol (DON) detection in wheat, barley, corn, and cereal products
  • Zearalenone (ZON) detection in corn and corn-derived products
  • Feed safety analysis and contamination screening
  • Regulatory compliance testing (EU, FDA, and international standards)
  • Mycotoxin profiling in food and agricultural commodities
  • Research and development in food safety laboratories
  • High-throughput mycotoxin screening workflows

Frequently Asked Questions

Are these columns suitable for LC-MS/MS analysis?
Yes. SENSIColumn IAC columns are fully compatible with LC-MS/MS and HPLC instrumentation, providing efficient sample cleanup and concentration prior to analytical separation.
Can a single column be used for both DON and ZON extraction?
These columns are specifically developed for simultaneous extraction of both DON and ZON from the same sample, making them ideal for comprehensive mycotoxin screening.
Do these columns cross-react with other trichothecenes?
Yes. The columns show 100% cross-reactivity with Nivalenol (NIV), 15-Acetyl-DON, and 3-Acetyl-DON, enabling detection of DON metabolites and structurally related compounds.
What sample preparation is recommended prior to column use?
Standard practice includes solvent extraction followed by dilution in buffer. Detailed protocols are provided with each package. Contact Novatek Analitik Sistemler A.Ş. for application-specific guidance.