SENSIColumn IAC immunoaffinity columns deliver high-sensitivity, reliable total aflatoxin determination for LC-MS/MS and HPLC-FLD analysis methods

  • 50 columns per package, 3 ml volume each
  • Working range: 0.04 – 200 ng total aflatoxin per IAC
  • Zero contamination: <0.04 ng (HPLC-FLD method LOD)
  • Total aflatoxin recovery: >90% ± 5%
  • Individual aflatoxin recovery rates: >90–95% ± 5%
  • Maximum column capacity: 1.8 µg total aflatoxin
  • Compatible with LC-MS/MS and HPLC-FLD detection

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

SENSIColumn IAC immunoaffinity columns are engineered for total aflatoxin analysis with superior sensitivity and dependable results. Each package contains 50 columns of 3 ml volume, optimized for LC-MS/MS and HPLC-FLD analytical methodologies.

Technical Specifications

Package Contents 50 columns per package, 3 ml each
Working Range 0.04 – 200 ng total aflatoxin per IAC
Zero Contamination Level <0.04 ng (HPLC-FLD method LOD)
Total Aflatoxin Recovery Rate >90% ± 5%
AFB1 Recovery Rate >95% ± 5%
AFB2 Recovery Rate >90% ± 5%
AFG1 Recovery Rate >95% ± 5%
AFG2 Recovery Rate >90% ± 5%
Maximum Column Capacity 1.8 µg total aflatoxin
AFB1 Cross-reactivity 100%
AFB2 Cross-reactivity 86%
AFG1 Cross-reactivity 101%
AFG2 Cross-reactivity 82%

Applications

  • Total aflatoxin analysis in food and feed commodities
  • Mycotoxin screening in grains, nuts, and dried fruits
  • Quality assurance testing in food manufacturing
  • Regulatory compliance and food safety monitoring
  • Toxicology research and environmental analysis
  • Sample pre-concentration for LC-MS/MS
  • HPLC-FLD method development and validation

Frequently Asked Questions

Which analytical techniques are compatible with these columns?
SENSIColumn IAC columns are designed for LC-MS/MS and HPLC-FLD (High-Performance Liquid Chromatography with Fluorescence Detection) analytical platforms.
What is the quantifiable working range?
The working range spans 0.04 – 200 ng total aflatoxin per column, accommodating low, medium, and high concentration samples.
What is the breakthrough capacity?
Maximum column capacity is 1.8 µg total aflatoxin, ensuring optimal flow rates and analytical performance.
What recovery rates should I expect?
AFB1: >95% ± 5%, AFB2: >90% ± 5%, AFG1: >95% ± 5%, AFG2: >90% ± 5%, with total aflatoxin recovery >90% ± 5%.
What is the background contamination level?
Zero contamination design with detection limit <0.04 ng as determined by HPLC-FLD methodology.