Stoklu siparişleriniz aynı gün kargoda!

Immunoaffinity Columns for Zearalenone (ZON)

Fiyat Sorunuz

SENSIColumn IAC immunoaffinity columns for high-sensitivity zearalenone analysis via LC-MS/MS and HPLC-FLD methods.

  • High-specificity immunoaffinity interaction for zearalenone and structural analogs
  • 50 columns per package, 3 ml volume each
  • Compatible with LC-MS/MS and HPLC-FLD instrumental platforms
  • Recovery rate guaranteed >85%
  • Working range: 5–500 ng ZON per column
  • Maximum column binding capacity: 2.7 µg ZON
  • Zero contamination: <5 ng (HPLC-FLD LOD)
  • Cross-reactivity with zearalenol metabolites (86–99%)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

SENSIColumn IAC immunoaffinity columns are specifically engineered for zearalenone (ZON) analysis, delivering high analytical sensitivity and reproducible quantitative results. Each package contains 50 prepacked columns with 3 ml bed volume, optimized for both LC-MS/MS and HPLC-FLD detection methodologies. These columns provide efficient sample cleanup and analyte pre-concentration with minimal matrix interference.

Technical Specifications

Package Contents 50 columns / 1 package, 3 ml per column
Working Range 5–500 ng ZON per IAC
Column Zero Contamination <5 ng (HPLC-FLD method LOD)
Recovery Rate (Guaranteed) >85%
Maximum Column Binding Capacity 2.7 µg ZON

Applications

  • Zearalenone determination in cereal grains and grain-based products
  • Mycotoxin screening in animal feed and pet food matrices
  • Food safety and regulatory compliance testing (EU, FDA limits)
  • Quantitative analysis of zearalenone and metabolites in biological fluids
  • Quality assurance in food processing and agricultural commodity inspection
  • Research and development in food authenticity and contamination studies

Frequently Asked Questions

What analytical techniques are these columns compatible with?
SENSIColumn IAC columns are optimized for LC-MS/MS and HPLC-FLD (fluorescence detection) methodologies. They function as efficient sample preparation tools for multi-residue or targeted analyte determination.
What is the maximum sample load per column?
The maximum column binding capacity is 2.7 µg ZON. Working range is 5–500 ng ZON per column for optimal performance within linear response.
What does the >85% recovery rate represent?
This guaranteed recovery rate indicates the percentage of spiked zearalenone that is successfully retained and eluted from the column under standard analytical protocols.
Do these columns show cross-reactivity with zearalenone metabolites?
Yes. The antibody exhibits high cross-reactivity: α-Zearalanol (99%), α-Zearalenol (97%), β-Zearalanol (94%), and β-Zearalenol (86%). This enables detection of metabolite variants.
What contaminant or blank levels should I expect?
Column contamination is <5 ng (below the HPLC-FLD method limit of detection), ensuring reliable baseline signals for low-level quantitation.