Immunoaffinity Columns for Fumonisins Analysis

Fiyat Sorunuz

SENSIColumn IAC immunoaffinity columns for high-sensitivity detection of Fumonisin B1 and B2 in LC-MS/MS and HPLC analysis

  • High-specificity immunoaffinity extraction for FB1 and FB2 toxins
  • Recovery rates >85% for both Fumonisin B1 and B2
  • Zero contamination <1 ng per column (method detection limit)
  • 3 ml column volume optimized for efficient sample throughput
  • Compatible with LC-MS/MS and HPLC instrumentation
  • 50 columns per package for economical batch analysis

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

SENSIColumn IAC immunoaffinity columns deliver high sensitivity and reliable results for Fumonisin B1 (FB1) and Fumonisin B2 (FB2) toxin analysis. Each package contains 50 columns with 3 ml capacity per column, suitable for advanced LC-MS/MS or HPLC analytical methods. These columns provide superior selectivity through antibody-based affinity binding technology, ensuring efficient sample purification and pre-concentration before instrumental analysis.

Technical Specifications

Package Content 50 columns/package, 3 ml per column
Working Range 1000 ng FB1/FB2 per IAC
Recovery Rate – Fumonisin B1 >85%
Recovery Rate – Fumonisin B2 >85%
Maximum Column Capacity 6 µg Fumonisin B1
Cross Reactivity – Fumonisin B1 100%
Cross Reactivity – Fumonisin B2 130%

Applications

  • Quantitative analysis of fumonisins in cereal grains and grain-based products
  • Mycotoxin screening in animal feed and feed ingredients
  • Regulatory compliance testing for food and feed safety
  • Pre-concentration and purification in multi-mycotoxin LC-MS/MS methods
  • Quality assurance in grain processing facilities
  • Research and development in food safety applications

Frequently Asked Questions

What is the recommended flow rate for these IAC columns?
Flow rates of 1-5 ml/min are typical for immunoaffinity columns. Consult the detailed application guide or contact technical support for specific method optimization.
Can these columns be used with different sample matrices?
Yes, SENSIColumn IAC columns are compatible with multiple matrices including cereal extracts, feed samples, and other grain-based products. Sample preparation protocols should be validated for each matrix.
What is the shelf life of these columns?
Storage at 2-8°C in the original packaging provides optimal column stability. Refer to the product documentation for detailed shelf life information.
Are these columns compatible with automated sample preparation systems?
These columns are suitable for both manual and automated extraction workflows. Compatibility with specific instruments should be verified with technical support.
What is the typical sample volume for analysis?
Sample volumes of 1-10 ml are typical, depending on expected fumonisin concentration and the specific analytical method being employed.