  • Working range: 0.04–50 ng Aflatoxin M1 per IAC
  • Recovery rate: 85%
  • Column capacity: 0.9 µg Aflatoxin M1
  • Blank contamination: <0.04 ng (HPLC-FLD detection limit)
  • Cross-reactivity: AFB1 98%, AFB2 99%, AFG1 50%, AFG2 98%
  • 3 ml column volume, 10/30/50/100-column package options

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

BIOTEZ IAC Aflatoxin M1 is an immunoaffinity column developed for sample cleanup and analyte enrichment prior to Aflatoxin M1 determination in milk and dairy products. Designed for use with HPLC-FLD instrumentation, it is well-suited for food safety laboratory analysts conducting mycotoxin analysis.

The column enables Aflatoxin M1 quantification in the 0.04–50 ng range and delivers reliable results with an 85% recovery rate. Due to its antibody-based design, it demonstrates cross-reactivity with Aflatoxin B1, B2, G1, and G2, providing additional utility in total aflatoxin screening workflows. Package options are available in 10, 30, 50, or 100-column configurations to accommodate varying sample throughput requirements.

With a low blank contamination level (<0.04 ng, HPLC-FLD detection limit) and a column capacity of 0.9 µg, both sensitive and reproducible analytical results are achieved.

Technical Specifications

Manufacturer BBI Solutions
Mycotoxin Type Aflatoxin M1
Column Volume 3 ml
Package Options 10 columns (BTAFM311005), 30 columns (BTAFM311030), 50 columns (BTAFM311050), 100 columns (BTAFM31100)
Working Range 0.04–50 ng Aflatoxin M1 (per IAC)
Blank Contamination <0.04 ng (HPLC-FLD detection limit)
Recovery Rate 85% (Aflatoxin M1)
Column Capacity 0.9 µg Aflatoxin M1
Cross-Reactivity AFM1 100%, AFB1 98%, AFB2 99%, AFG1 50%, AFG2 98%

Applications

  • Sample cleanup and preparation for Aflatoxin M1 analysis in milk and dairy products
  • Mycotoxin quantification using HPLC-FLD in food safety laboratories
  • Additional verification in total aflatoxin screening applications

Frequently Asked Questions

Which instrument is this column compatible with?
The column is designed for use with HPLC-FLD (High-Performance Liquid Chromatography with Fluorescence Detection) systems.
Is this column specific to Aflatoxin M1 only?
No, the column demonstrates cross-reactivity with Aflatoxins B1, B2, G1, and G2, making it suitable for total aflatoxin screening applications as well.
What package sizes are available?
Package options are available in 10, 30, 50, and 100-column configurations, all with 3 ml column volume.