Stoklu siparişleriniz aynı gün kargoda!

Atago PEN-SW WV Immersion-Type Digital Refractometer – Salinity Measurement (g/100mL)

Fiyat Sorunuz

Atago PEN-SW WV is an immersion-type digital refractometer that measures salt concentration in water within the range of 0.0-33.0 g/100mL. It delivers rapid, precise results for water treatment and seawater analysis applications.

  • 0.0-33.0 g/100mL measurement range
  • ±0.2% accuracy
  • Automatic temperature compensation (10-40°C)
  • Immersion-type, fast and user-friendly operation
  • Atago brand reliability

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Atago PEN-SW WV is a digital immersion-type (dip-type) refractometer designed to measure salinity concentration in water using the g/100mL unit. It provides a practical measurement solution for operators performing water quality control, seawater desalination, and industrial salinity monitoring.

The instrument operates on a 'dip, touch, read' principle, delivering quick results without sample preparation. The 0.0-33.0 g/100mL measurement range covers a broad salinity spectrum from freshwater to seawater levels. Built-in automatic temperature compensation (10-40°C) reduces measurement errors caused by ambient temperature fluctuations, ensuring reliable field results.

With an accuracy of ±0.2%, the PEN-SW WV delivers sufficient precision for process control and quality assurance applications in water treatment facilities. Its compact, portable design makes it equally suitable for field and laboratory salinity measurements.

Technical Specifications

Manufacturer Atago
Measurement Range 0.0-33.0 g/100mL
Accuracy ±0.2%
Temperature Compensation Automatic, 10-40°C
IP65 Protection Not rated
Device Type Immersion-Type (Dip-type) Digital Refractometer

Applications

  • Salinity control in water treatment and desalination plants
  • Seawater salinity analysis
  • Industrial process water quality monitoring
  • Field and laboratory salinity measurements

Frequently Asked Questions

What unit of measurement does the PEN-SW WV use?
The instrument measures salinity concentration in g/100mL (grams of salt per 100 mL of solution).
Does temperature variation affect measurement results?
No. The instrument features automatic temperature compensation within the 10-40°C range, automatically correcting for temperature-induced measurement errors.
Is the device water-resistant?
The instrument is not certified with IP65 water/dust protection, so it should be handled with care during use.