Stoklu siparişleriniz aynı gün kargoda!

Romer Labs AgraStrip® Macadamia Nut Allergen Strip Test – 1 Box (10 Tests)

Fiyat Sorunuz

Rapid and qualitative lateral flow (LFD) strip test for detecting macadamia nut residue in raw materials, finished products, rinse water, and environmental surfaces. 10 tests/box.

  • Rapid results using strip test (LFD) principle
  • Qualitative result type (present/absent)
  • Detection limit: 2 ppm macadamia; 2 µg/25 cm² (swab test)
  • Storage temperature: 15°C - 25°C
  • 10 tests per box
  • Applicable to raw materials, finished products, rinse water, and environmental samples

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The AgraStrip® Macadamia Nut test kit is a lateral flow device (LFD) developed for on-site detection of macadamia nut allergen residues in food production lines and laboratory environments. It delivers rapid results on raw materials, finished food products, beverages, rinse water, and environmental surface samples.

The kit provides simple and rapid qualitative detection without requiring complex laboratory equipment; making it a practical solution for production and quality control teams when allergen cross-contamination risk assessment needs to be performed quickly. Manufactured using Romer Labs' proven strip test technology.

The box contains 10 tests and results are evaluated qualitatively (present/absent).

Technical Specifications

Manufacturer Romer Labs
Allergen Type Macadamia nut
Test Principle Strip Test (LFD)
Kit Format Strip
Result Type Qualitative
Detection Limit 2 ppm macadamia; 2 µg/25 cm² (swab test)
Storage Temperature 15°C – 25°C
Test Count 10 tests/box

Applications

  • Allergen cross-contamination control in food processing facilities
  • Raw material and finished product allergen screening
  • Rinse water testing following equipment cleaning
  • Production line surface allergen monitoring via swab sampling

Frequently Asked Questions

Which sample types can be tested with this kit?
The test can be used on raw materials, finished food products, beverages, rinse water, and environmental surface samples (swab).
How quickly are results obtained and what type of result does it provide?
The test provides qualitative results, rapidly indicating macadamia presence as present/absent; it does not provide quantitative values.
How should the kit be stored?
The kit should be stored at room temperature between 15°C – 25°C.