Immunoaffinity column for sample clean-up in total aflatoxin (B1, B2, G1, G2) analysis. Delivers high recovery rates and low detection limits with HPLC-FLD.

This product is currently out of stock and unavailable.

  • Working range: 0.04–200 ng total aflatoxin per IAC
  • Column capacity: 1.8 µg total aflatoxin
  • Total aflatoxin recovery: >90%±5%
  • Cross-reactivity: AFB1 100%, AFG1 101%, AFB2 86%, AFG2 82%
  • 3 ml volume, available in 10/30/50/100 column pack sizes
  • Manufactured by BBI Solutions

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

BioTeZ IAC Aflatoxin Total columns are immunoaffinity columns designed for extract clean-up prior to total aflatoxin (B1, B2, G1, G2) determination in food and feed samples. These columns provide precise and reproducible results for laboratories operating HPLC-FLD systems.

The column is effective across a working range of 0.04–200 ng total aflatoxin per IAC with a column capacity of 1.8 µg. Recovery rates are measured at >90%±5% for total aflatoxin, >95%±5% for AFB1, >90%±5% for AFB2, >95%±5% for AFG1, and >90%±5% for AFG2. Cross-reactivity values have been determined at 100% for AFB1, 101% for AFG1, 86% for AFB2, and 82% for AFG2.

Manufactured by BBI Solutions, these columns are supplied in 3 ml format with flexible packaging options (10, 30, 50, 100 columns), providing suitable solutions for both low-throughput laboratories and high-volume analytical facilities.

Technical Specifications

Mycotoxin Type Total aflatoxin (B1, B2, G1, G2)
Working Range 0.04–200 ng/IAC
Column Capacity 1.8 µg total aflatoxin
Detection Limit (HPLC-FLD) <0.04 ng
Recovery (Total Aflatoxin) >90%±5%
Recovery (AFB1) >95%±5%
Recovery (AFB2) >90%±5%
Recovery (AFG1) >95%±5%
Recovery (AFG2) >90%±5%
Cross-Reactivity (AFB1/AFB2/AFG1/AFG2) 100% / 86% / 101% / 82%
Volume 3 ml
Pack Options 10, 30, 50, 100 columns (BTAF310005, BTAF310030, BTAF31050, BTAF31000)
Manufacturer BBI Solutions

Applications

  • Extract clean-up prior to total aflatoxin analysis in food and feed samples
  • Aflatoxin B1, B2, G1, G2 determination using HPLC-FLD methodology
  • Routine sample preparation in mycotoxin quality control laboratories

Frequently Asked Questions

Which aflatoxin types are covered by this column?
The column is designed for total aflatoxin determination including AFB1, AFB2, AFG1, and AFG2.
What sample volume does the column capacity support?
The column has a capacity of 1.8 µg total aflatoxin; reliable results are obtained when this capacity is not exceeded.
What package sizes are available?
Packs are available in 3 ml volume containing 10, 30, 50, or 100 columns per package.