Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-68S Potassium Dichromate Refractometer

Fiyat Sorunuz

Digital handheld refractometer measuring potassium dichromate (K₂Cr₂O₇) solution concentration in 0.0-15.0% range with ±0.2% accuracy in 3 seconds using 2-3 sample drops.

  • 0.0-15.0% K₂Cr₂O₇ measurement range
  • ±0.2% concentration accuracy
  • Result in approximately 3 seconds
  • 2-3 drops (≈0.3 mL) sample sufficient
  • Automatic temperature compensation (10.0-40.0°C)
  • IP65 protection class, battery powered

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-68S is a specialized digital refractometer manufactured by Atago for rapid and precise measurement of potassium dichromate (K₂Cr₂O₇) solution concentration. It is designed for laboratories performing redox titrations, chromating processes, and quality control applications.

The instrument delivers ±0.2% accuracy across the 0.0-15.0% measurement range and provides reliable results across 10.0-40.0°C through automatic temperature compensation. Measurements are completed in approximately 3 seconds using only 2-3 drops (approximately 0.3 mL) of sample, enabling practical rapid process control in demanding applications. The IP65 protection rating ensures durability in field and industrial environments, with operation powered by 2 AAA batteries.

Compared to manual reading methods, the PAL-68S delivers more consistent and reproducible results, providing a reliable measurement solution for processes where concentration control is critical.

Technical Specifications

Model PAL-68S
Catalog Number 4468
Measurement Range K₂Cr₂O₇: 0.0-15.0%
Temperature Range 10.0-40.0°C
Resolution 0.1% (K₂Cr₂O₇)
Accuracy K₂Cr₂O₇: ±0.2% / Temperature: ±1°C
Measurement Time Approximately 3 seconds
Sample Volume 2-3 drops (≈0.3 mL)
Power Source 2 × AAA Battery
Protection Class IP65

Applications

  • Potassium dichromate solution concentration control
  • Reference solution preparation in redox titrations
  • Quality control in chromating processes

Frequently Asked Questions

Can the PAL-68S be used for substances other than potassium dichromate?
No, the instrument is specifically calibrated for K₂Cr₂O₇ concentration measurement.
What volume of sample is required for measurement?
2-3 drops, approximately 0.3 mL of sample is sufficient.
Is measurement accuracy affected by temperature fluctuations?
No, automatic temperature compensation ensures accurate results within the 10.0-40.0°C operating range.