Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-57S Nickel Sulfate Refractometer

Fiyat Sorunuz

Digital handheld refractometer for simultaneous measurement of nickel sulfate (NiSO₄) concentration and temperature in aqueous solutions. Designed for rapid, minimal-sample quality control in galvanic plating and electrolyte manufacturing.

  • NiSO₄ measurement range 0.0–10.0%, 0.1% resolution
  • ±0.2% NiSO₄ accuracy
  • Simultaneous temperature measurement: 10.0–40.0°C, ±1°C accuracy
  • IP65 protection rating
  • Measurement with only 2–3 drops of sample
  • Atago brand digital handheld refractometer

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-57S is a digital handheld refractometer specifically calibrated for measuring the concentration of nickel sulfate (NiSO₄) in aqueous solutions. Developed for process control specialists in galvanic plating and electrolyte production lines.

The instrument measures NiSO₄ concentration in the range of 0.0–10.0% with 0.1% resolution and ±0.2% accuracy, while simultaneously displaying temperature in the range of 10.0–40.0°C with 0.1°C resolution. Only 2–3 drops of sample are required, enabling rapid and practical quality control checks directly on the production line. With IP65 protection rating, it operates reliably in humid and dusty industrial environments.

Compared to conventional spectrophotometric analysis methods, the PAL-57S delivers significantly faster results, making it a practical alternative for quality control and production teams committed to maintaining coating quality.

Technical Specifications

Model PAL-57S
Catalog Number 4457
Measurement Scale Nickel Sulfate (g/100g) + Temperature
NiSO₄ Range 0.0 – 10.0%
NiSO₄ Resolution 0.1%
NiSO₄ Accuracy ±0.2%
Temperature Range 10.0 – 40.0°C
Temperature Resolution 0.1°C
Temperature Accuracy ±1°C
Sample Volume 2–3 drops
IP Protection Rating IP65
Temperature Compensation None
Manufacturer Atago

Applications

  • Electrolyte concentration control in galvanic plating baths
  • Quality control in nickel sulfate production and mixing processes
  • Field measurement in electrolyte solution preparation

Frequently Asked Questions

What sample volume is required for measurement with the PAL-57S?
Only 2–3 drops of sample are needed for measurement, which streamlines rapid quality control checks on the production line.
Does the instrument have automatic temperature compensation?
No, the instrument does not feature automatic temperature compensation; however, it simultaneously measures and displays temperature with 0.1°C resolution.
In which environments can the PAL-57S be used?
With its IP65 protection rating, the instrument operates reliably in humid and dusty industrial environments.