Stoklu siparişleriniz aynı gün kargoda!

Cesium Chloride Refractometer PAL-42S (Atago) – CsCl Density Gradient Measurement

Fiyat Sorunuz

Atago PAL-42S is a digital handheld refractometer that measures cesium chloride solution concentration with just 2-3 sample drops. It offers ±0.4% accuracy across the 0.0-60.0% CsCl range and is ideal for molecular biology and biochemistry laboratories.

  • 0.0-60.0% CsCl measurement range
  • ±0.4% accuracy
  • 2-3 drop sample measurement
  • IP65 chemical protection class
  • 2 x AAA battery operation
  • Compact dimensions: 5.5 x 3.1 x 10.9 cm, 100 g

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-42S is a digital handheld refractometer developed by Atago for rapid and low-volume measurement of cesium chloride (CsCl) solution concentration. It is applicable for verification of CsCl solution preparation in DNA/RNA isolation and density gradient centrifugation procedures.

The instrument provides ±0.4% accuracy within the 0.0-60.0% CsCl measurement range while requiring only 2-3 sample drops, ensuring conservation of valuable specimens. With IP65 protection class, it demonstrates resistance to chemical exposure. The device lacks automatic temperature compensation, therefore measurement results should be evaluated with consideration to ambient temperature.

Its compact and lightweight construction (5.5 x 3.1 x 10.9 cm, 100 g) enables portable field use and operates on 2 x AAA batteries. It represents a practical measurement solution for researchers in molecular biology and biochemistry laboratories performing CsCl solution verification.

Technical Specifications

Brand Atago
Model PAL-42S
Measurement Range 0.0-60.0% CsCl
Accuracy ±0.4%
Sample Volume 2-3 drops
Protection Class IP65
Temperature Compensation None
Power Source 2 x AAA Batteries
Dimensions 5.5 x 3.1 x 10.9 cm
Weight 100 g

Applications

  • Cesium chloride (CsCl) solution concentration verification
  • Gradient preparation verification in DNA/RNA isolation protocols
  • Solution verification for density gradient centrifugation procedures

Frequently Asked Questions

What temperature compensation method does the PAL-42S use?
The instrument does not feature automatic temperature compensation; measurements should be evaluated at ambient laboratory temperature.
What sample volume is required for measurement?
Only 2-3 drops are required, which ensures preservation of valuable specimens.
Is the PAL-42S calibrated exclusively for CsCl?
Yes, the PAL-42S is specifically calibrated for cesium chloride concentration measurement.