The PAL-25S is a digital handheld refractometer that measures inulin concentration and temperature in inulin solutions using just 2-3 sample drops. It provides rapid quality control for prebiotic and functional food manufacturing.

  • 0.0-15.0% inulin measurement range
  • ±0.2% inulin and ±1°C temperature accuracy
  • 0.1% inulin and 0.1°C temperature resolution
  • 2-3 sample drops, ~3 second measurement time
  • IP65 water-resistant, 100g compact body
  • Portable operation with 2 x AAA batteries

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Atago PAL-25S is a specialized digital handheld refractometer designed for concentration control of inulin-based food and nutraceutical products. With a measurement range of 0.0-15.0% inulin and temperature measurement capability of 10.0-40.0°C, it delivers fast and reliable results in prebiotic food production and formulation development processes.

The device operates with ±0.2% inulin and ±1°C temperature accuracy, providing 0.1% and 0.1°C resolution. Requiring only 2-3 sample drops, it produces results in approximately 3 seconds, enabling rapid sample control on production lines. Its IP65 water-resistant housing allows safe operation in wet manufacturing environments; with a weight of 100g and compact dimensions (5.5×3.1×10.9 cm), it offers excellent portability.

The PAL-25S is a practical quality control tool for food technology laboratories, prebiotic and functional food manufacturers, and the nutraceutical industry. Powered by 2 x AAA batteries, it is suitable for field measurements as well.

Technical Specifications

Model PAL-25S
Catalog Number 4425
Measurement Parameter Inulin and Temperature
Inulin Range 0.0 – 15.0% (g/100g)
Temperature Range 10.0 – 40.0°C
Inulin Resolution 0.1%
Temperature Resolution 0.1°C
Inulin Accuracy ±0.2%
Temperature Accuracy ±1°C
Operating Temperature 10 – 40°C
Sample Volume 2-3 drops
Measurement Time Approximately 3 seconds
Power Source 2 x AAA Batteries
Protection Rating IP65
Dimensions 5.5 × 3.1 × 10.9 cm
Weight 100g
Temperature Compensation None

Applications

  • Inulin concentration control in prebiotic food production
  • Functional food and nutraceutical formulation development
  • Rapid sample quality control on production lines

Frequently Asked Questions

How many drops of sample are needed for measurement with the PAL-25S?
2-3 drops of sample are sufficient, with measurement completed in approximately 3 seconds.
Does the device have automatic temperature compensation?
No, the PAL-25S does not feature automatic temperature compensation; measurement temperature is displayed separately.
Can the device be used in wet environments?
Yes, thanks to its IP65 water-resistant housing, it can be safely used in humid environments such as production lines.