Stoklu siparişleriniz aynı gün kargoda!

Aflatoxin M1 Milk ELISA Kit I’screen AFLA M1

Fiyat Sorunuz

Quantitative immunological assay for aflatoxin M1 detection in bovine milk, skimmed milk, and milk powder

This product is currently out of stock and unavailable.

  • Over 20 years of market proven performance
  • 100% compliance in external quality assurance program audits
  • First AOAC-approved immunological test for milk aflatoxin M1 analysis
  • Recognition from 50+ reference laboratories
  • Direct analysis of whole milk without sample preparation
  • Rapid results: 30 minutes without calibration requirement
  • Compatible with cheese, yogurt, and UHT milk analysis
  • Low limits of detection: 5 ng/L raw milk, 50 ng/L milk powder

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

I'screen AFLA M1 Milk is a quantitative immunological assay designed for the analysis of aflatoxin M1 in raw bovine milk, skimmed milk, and milk powder. With over 20 years of market presence and 100% compliance in annual external quality assurance program audits, this assay has gained recognition from over 50 reference laboratories. It is the first immunological test to obtain AOAC approval for aflatoxin M1 analysis in raw bovine milk, skimmed milk, and milk powder. The kit utilizes identical reagents, components, and procedures as I'screen AFLA M1 milk, with additional specialized cheese buffer and protocols for analysis of cheese, hard cheese, yogurt, and processed milk (UHT). Designed for laboratories with limited analytical capacity, it enables direct analysis of whole milk without sample preparation and delivers calibration-independent quantitative results within 30 minutes.

Technical Specifications

SKU (96 tests) HU0040001
SKU (48 tests) HU0040021
SKU (192 tests) HU0040041
Analysis Principle Microplate competitive enzyme immunological assay
Format 96-well microplate
Assay Time 75 minutes
Applicable Sample Types Raw bovine milk, Skimmed milk, Milk powder
Limit of Detection (LOD) – Liquid Milk 5 ng/L (0.005 ppb)
Limit of Detection (LOD) – Milk Powder 50 ng/L (0.05 ppb)
Sample Preparation – Raw Milk Cooling, centrifugation (optional)
Sample Preparation – Milk Powder Dilution
Specificity – Aflatoxin M1 100%
Specificity – Aflatoxin M2 16%
Specificity – Aflatoxin B1 <0.1%
Specificity – Aflatoxin B2 <0.1%
Specificity – Aflatoxin G1 <0.1%
Specificity – Aflatoxin G2 <0.1%
Compliance ISO 14675:2003 (IDF 186:2003)

Applications

  • Raw bovine milk screening for aflatoxin M1 contamination
  • Skimmed milk quality control testing
  • Milk powder mycotoxin analysis
  • Dairy product quality assurance programs
  • Cheese and hard cheese contamination assessment
  • Yogurt safety testing
  • Ultra-high temperature (UHT) processed milk screening
  • Export compliance verification for dairy products
  • Feed to food pathway contamination monitoring

Frequently Asked Questions

What is the typical turnaround time for aflatoxin M1 detection?
The standard assay time is 75 minutes. The B ZERO AFLA M1 variant delivers results in approximately 30 minutes without requiring calibration.
Can this kit detect aflatoxins other than M1?
The kit is specifically designed for aflatoxin M1 with 100% specificity. It shows minimal cross-reactivity with other aflatoxins (M2: 16%, B1/B2/G1/G2: <0.1%).
What sample types are compatible with this assay?
The kit is validated for raw bovine milk, skimmed milk, and milk powder. Additional protocols are available for cheese, yogurt, and UHT milk analysis.
Is sample preparation required before analysis?
For raw milk, only optional cooling and centrifugation are recommended. Milk powder requires dilution. The B ZERO AFLA M1 variant enables direct analysis of whole milk without preparation.
What regulatory standards does this assay meet?
The assay complies with ISO 14675:2003 (IDF 186:2003) guidelines and has obtained AOAC approval for milk aflatoxin M1 analysis.
How long has this product been on the market?
I'screen AFLA M1 milk has maintained continuous market presence for over 20 years with established performance in external quality assurance programs.
What is the detection capability difference between liquid milk and powder?
Limit of Detection for raw/skimmed milk is 5 ng/L, while milk powder achieves 50 ng/L LOD due to the dilution requirement in sample preparation.