Stoklu siparişleriniz aynı gün kargoda!

Awareness Technology Stat Fax 4200 ELISA Plate Reader

Fiyat Sorunuz

Monochromatic/bichromatic ELISA microplate reader that scans 96-well microtitre plates in approximately 10 seconds. Provides accurate and rapid absorbance measurement for clinical and veterinary laboratories.

  • Monochromatic photometer reading 96 wells in ~10 seconds (340-750 nm)
  • ±1% photometric accuracy with drift <0.005 A in 8 hours
  • Touch-sensitive LCD display with USB mouse interface
  • Temperature control with 25°C, 37°C, and ambient temperature options
  • Multiple calculation modes: linear, sigmoidal, polynomial regression, cutoff absorbance
  • Integrated thermal line printer

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Stat Fax 4200 is a semi-automated microplate reader designed for ELISA testing in clinical biochemistry, veterinary, and food safety laboratories. Operating in the 340–750 nm wavelength range with a monochromatic photometer system and rapid scanning capability of 96 wells in approximately 10 seconds, it accelerates routine test workflows.

The instrument features a user-friendly interface with a touch-sensitive LCD screen and USB mouse support; an open system with user-defined protocols enables creation of diverse assay protocols. With ±1% photometric accuracy and drift not exceeding 0.005 A in 8 hours, it delivers stable results during extended measurement sessions. Multiple calculation modes—including single-point calibration, linear/sigmoidal regression, and polynomial regression—accommodate various ELISA kit protocols.

Lacking a built-in wash head, manual washing is required; therefore it functions as a semi-automated analyzer rather than a fully automated system. Temperature flexibility with 25°C, 37°C, and ambient temperature options supports temperature-sensitive assays. Its compact footprint (7.5×13×16.5 inches) and 6.80 kg weight minimize bench space requirements.

Technical Specifications

Optical Reader System Monochromatic photometer (340–750 nm)
Sample Volume 5 µL – 1.0 mL
Plate Format 96-well microtitre plate
Temperature Control 25°C, 37°C, and ambient temperature
Wash Unit None; manual washing required
Photometric Accuracy ± 1%
Photometric Range -0.20 to 4.0 Absorbance units (A)
Stability Drift not exceeding 0.005 A in 8 hours
Scanning Speed ~10 seconds for 96 wells
Filters IAD, 10 nm FWHM, 405-700 nm
Illumination Long-life halogen lamp
Microprocessor eZ80
Plate Transport Stepper motor
Display Interactive touch-screen LCD
Interface USB mouse
Printer Thermal, 20 characters per line + graphics
Dimensions (H × W × D) 7.5 × 13 × 16.5 inches
Weight 6.80 kg
Power Requirements 115V/230V AC, 50–60 Hz (auto-sensing)
Housing Flame-retardant ABS plastic

Applications

  • ELISA testing in clinical biochemistry laboratories
  • Antibody/antigen screening in veterinary diagnostic laboratories
  • Residue and contaminant testing in food safety laboratories

Frequently Asked Questions

Does the Stat Fax 4200 perform automatic plate washing?
No, the instrument lacks a built-in wash head; plate washing must be performed manually or with a separate plate washer.
What wavelength range does it operate in?
It operates with a monochromatic photometer in the 340–750 nm wavelength range; IAD filters are used between 405–700 nm.
How many wells are read simultaneously and what is the reading time?
Standard 96-well microtitre plates are read in approximately 10 seconds.