Stoklu siparişleriniz aynı gün kargoda!

Immunoaffinite Columns IAC Combi Afla+Ochra

Fiyat Sorunuz

High-performance immunoaffinite cleanup columns for simultaneous Aflatoxin and Ochratoxin extraction

This product is currently out of stock and unavailable.

  • Working range: 0.04–200 ng/IAC (Aflatoxins + Ochratoxin)
  • Superior recovery rates: >85% for aflatoxins, >90% for OTA
  • Blank contamination: <0.04 ng (HPLC-FLD detection limit)
  • Dual-analyte capability for simultaneous Afla/Ochra determination
  • Proven cross-reactivity profile for multiple aflatoxin forms

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Advanced immunoaffinite affinity columns (IAC) designed for selective extraction and concentration of Aflatoxins (B1, B2, G1, G2) and Ochratoxin A from food and feed matrices. The combination cartridge provides efficient sample cleanup and preconcentration prior to HPLC-FLD analysis with excellent recovery rates and minimal blank contamination.

Technical Specifications

Working Range 0.04–200 ng/IAC (Aflatoxins + Ochratoxin)
Blank Contamination <0.04 ng (HPLC-FLD detection limit)
Column Capacity 1.8 μg Aflatoxins & 3 μg Ochratoxin
Recovery Rate – Aflatoxin B1 (AFB1) >95% ± 5%
Recovery Rate – Aflatoxin B2 (AFB2) >85% ± 5%
Recovery Rate – Aflatoxin G1 (AFG1) >85% ± 5%
Recovery Rate – Aflatoxin G2 (AFG2) >85% ± 5%
Recovery Rate – Total Aflatoxin >85% ± 5%
Recovery Rate – Ochratoxin A (OTA) >90% ± 5%
Cross-reactivity – AFB1 100%
Cross-reactivity – AFB2 99%
Cross-reactivity – AFG1 48%
Cross-reactivity – AFG2 34%
Cross-reactivity – OTA 100%
Cross-reactivity – OTB 103%

Applications

  • Food and feed safety testing for mycotoxin contamination
  • Aflatoxin screening in cereals, grains, nuts, and spices
  • Ochratoxin A determination in contaminated samples
  • Pre-analytical sample cleanup for HPLC-FLD analysis
  • Multi-mycotoxin analysis and compliance testing
  • Regulatory food testing and quality assurance

Frequently Asked Questions

Can I use these columns for both Aflatoxins and Ochratoxin simultaneously?
Yes, the IAC Combi Afla+Ochra columns are specifically designed for simultaneous extraction of both Aflatoxins (B1, B2, G1, G2) and Ochratoxin A in a single pass.
What is the maximum sample volume the column can process?
The column capacity is 1.8 μg for Aflatoxins and 3 μg for Ochratoxin per cartridge.
Which analytical method is recommended?
HPLC-FLD (High-Performance Liquid Chromatography with Fluorescence Detection) is recommended for optimal results.