Stoklu siparişleriniz aynı gün kargoda!

TFA 31.1114 Laser Infrared Thermometer

Fiyat Sorunuz

Non-contact temperature measurement with laser targeting for precise readings on surfaces from distance or close range.

  • Single-button operation for ease of use
  • HACCP standard compliant
  • 1-second response time
  • Display of current, maximum, and minimum temperature readings
  • HOLD (freeze display) and lock function
  • Adjustable emissivity compensation
  • Temperature measurement range: -55...+250°C (-67...+482°F)
  • Measurement accuracy: ±2% or ±2°C
  • Measurement resolution: 0.1°C
  • Optical ratio: 6:1
  • Compact non-contact measurement technology

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The TFA 31.1114 is a pistol-grip infrared thermometer for non-contact surface temperature measurement of hot, hazardous, and hard-to-reach surfaces. Its lightweight, compact design enables quick and accurate readings without damaging the measured surface. Laser aiming ensures precise targeting of the measurement point, making it ideal for HACCP-compliant food safety applications and industrial temperature monitoring.

Technical Specifications

Temperature Range -55…+250°C (-67…+482°F)
Measurement Accuracy ±2% or ±2°C
Measurement Resolution 0.1°C
Response Time 1 second
Optical Ratio 6:1
Dimensions 52 x 21 x 104 mm
Weight 57 g
Battery 2x CR2032

Applications

  • HACCP-compliant food safety temperature monitoring
  • Industrial process control and equipment monitoring
  • Measurement of hot and hazardous surfaces
  • Temperature verification on hard-to-reach surfaces
  • Non-destructive surface temperature assessment
  • Thermal diagnostics and troubleshooting

Frequently Asked Questions

What is emissivity and why is it important?
Emissivity is the thermal radiation efficiency of a surface. Different materials emit heat differently—for example, black surfaces have different emissivity than polished surfaces. The TFA 31.1114 has adjustable emissivity settings to ensure accurate measurements across various surface types. Incorrect emissivity settings can result in measurement errors.
Is the TFA 31.1114 suitable for food industry applications?
Yes, this thermometer is HACCP (Hazard Analysis and Critical Control Points) compliant, making it suitable for food safety temperature monitoring and quality control applications.
Can this thermometer measure hot surfaces without contact?
Yes, the infrared non-contact technology allows safe temperature measurement of hot, hazardous, and inaccessible surfaces without risk of damage or operator injury.