Stoklu siparişleriniz aynı gün kargoda!

Standard Calibration Solution Set for Apera Instruments TN400 Portable Turbidity Meter

Fiyat Sorunuz

AMCO Clear® primary turbidity calibration standards (0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU) for accurate sensor calibration

  • EPA-approved non-toxic primary calibration standard
  • NIST traceable by particle size/distribution and optical density
  • Four concentration levels: 0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU
  • Maintains accuracy with natural suspension stability
  • Reliable readings across 0.02 NTU to 10,000 NTU range
  • Compatible with TN400 turbidity meter

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

AMCO Clear® turbidity standard solutions are EPA-approved primary calibration standards engineered for turbidity sensor calibration. These non-toxic, single-use solutions feature particle size/distribution and optical density traceable to NIST standards. The formulation demonstrates natural stability with no sedimentation from suspension, ensuring consistent performance throughout the product lifecycle.

Technical Specifications

Standard Solutions Included 0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU
Measurement Range 0.02 NTU to 10,000 NTU
Standard Type EPA-approved primary standard
Composition Submicron polymer suspension
Toxicity Non-toxic
Traceability NIST traceable

Applications

  • Drinking water quality analysis
  • TN400 turbidity meter calibration and verification
  • Laboratory and field testing protocols
  • Environmental water quality monitoring
  • Sensor accuracy validation
  • Routine maintenance calibration

Frequently Asked Questions

Are these standards approved for drinking water analysis?
Yes, AMCO Clear® solutions are EPA-approved primary calibration standards specifically formulated for drinking water analysis and turbidity measurement.
Are these solutions toxic?
No, AMCO Clear® solutions are non-toxic primary standards designed for safe handling in laboratory and field environments.
How is NIST traceability established?
Traceability is established through particle size/distribution and optical density measurements referenced to NIST standards.
Can these standards be used for readings above 800 NTU?
Yes, these standards enable reliable readings across the entire 0.02 NTU to 10,000 NTU range with proper dilution or combination protocols.