Stoklu siparişleriniz aynı gün kargoda!

HF Scientific Micro 100+ Laboratory Turbidimeter

Fiyat Sorunuz

Laboratory turbidity analyzer with 0-4,000 NTU measurement range and 0.0001 NTU resolution. Suitable for water quality laboratories and online turbidimeter verification.

  • 0-4,000 NTU automatic measurement range
  • Selectable resolution down to 0.0001 NTU
  • Dual measurement principle: nephelometric (<1,000 NTU) and ratio (>1,000 NTU)
  • Response time ≤3 seconds
  • 30 mL sample volume (minimum 27 mL)
  • White light (tungsten) / infrared (860nm LED) light source options

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

HF Scientific Micro 100+ (M100+™) is a precision laboratory turbidimeter designed for routine turbidity measurement in water quality laboratories and verification of online turbidimeters. It combines nephelometric and ratio measurement principles to deliver consistent results across both low and high turbidity levels.

The instrument offers an automatic measurement range of 0-4,000 NTU with selectable resolution down to 0.0001 NTU, making it applicable to a wide range of applications including drinking water, wastewater, and process water analysis. It operates on nephelometric principles below 1,000 NTU and transitions to ratio measurement above 1,000 NTU, ensuring reliable results at both low and high turbidity concentrations. With a response time of ≤3 seconds and a standard sample volume of 30 mL (minimum 27 mL), the M100+ provides rapid and convenient analysis.

Selectable light sources—white light (tungsten) and infrared (860nm LED)—enable compliance with various international standards including EPA 180.1 and ISO 7027. The instrument operates within a temperature range of 1°C to 40°C. Note that the M100+ does not feature IP65 rating or automatic temperature compensation, so operation in a controlled laboratory environment is recommended.

Technical Specifications

Model M100+™
Measurement Range 0 – 4,000 NTU (Automatic)
Measurement Principle Nephelometric (<1,000 NTU) / Ratio (>1,000 NTU)
Accuracy (Low Range) ±2% of reading or ±0.02 NTU (<40 NTU)
Accuracy (High Range) ±5% of reading (>40 NTU)
Resolution Selectable down to 0.0001 NTU
Response Time ≤3 seconds
Sample Volume 30 mL (minimum 27 mL)
Light Source White light (tungsten) / Infrared (860nm LED)
Operating Temperature 1°C – 40°C
IP Rating No IP65 protection
Temperature Compensation Not equipped

Applications

  • Routine turbidity measurement in drinking water and wastewater quality laboratories
  • Laboratory verification and validation of online turbidimeter instruments
  • High-precision process water testing at both low and high turbidity levels

Frequently Asked Questions

Which standards does the M100+ comply with?
The M100+ can perform measurements in compliance with EPA 180.1 and ISO 7027 standards through its selectable white light (tungsten) and infrared (860nm LED) light source options.
Does the M100+ have automatic temperature compensation?
No, the M100+ does not feature automatic temperature compensation. Measurements should be conducted within the specified operating temperature range of 1°C to 40°C.
What is the minimum sample volume required for measurement?
The standard sample volume is 30 mL, with a minimum allowable volume of 27 mL for measurement.