Stoklu siparişleriniz aynı gün kargoda!

SAL-T Salt Standards by Novasina

Fiyat Sorunuz

Saturated salt solution humidity reference standards in vapor-permeable membrane tablets

  • Saturated salt solution-based humidity standards
  • Vapor-permeable membrane technology for stable humidity generation
  • Wide range of humidity values from 4% to 97%
  • Compatible with Novasina LabStart-aw, LabSwift-aw, LabTouch-aw, and LabMaster-aw NEO analyzers
  • Can be used for both calibration and verification purposes
  • Each standard supplied in sealed protective container

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

SAL-T humidity standards are based on saturated salt solutions contained in humidity-permeable membrane plastic tablets. Each salt reference is supplied sealed in its own protective box. These humidity standards enable precise calibration and verification of laboratory moisture analyzers. Refer to your instrument's user manual to determine which calibration points are compatible with your specific device.

Technical Specifications

Humidity Value 4%, 6%, 11%, 23%, 33%, 43%, 53%, 58%, 75%, 84%, 90%, 97%
Technology Saturated salt solution in vapor-permeable membrane plastic tablet
Packaging Individual sealed boxes per salt reference
Applications Calibration and verification of water activity analyzers
Compatible Devices LabStart-aw, LabSwift-aw, LabTouch-aw, LabMaster-aw NEO

Applications

  • Calibration of laboratory moisture and water activity analyzers
  • Verification of analyzer accuracy and performance
  • Routine maintenance calibration programs
  • Quality control and compliance testing
  • Multi-point calibration protocols for food, pharmaceutical, and chemical industries

Frequently Asked Questions

What humidity values are available for SAL-T standards?
SAL-T standards are available in the following humidity values: 4%, 6%, 11%, 23%, 33%, 43%, 53%, 58%, 75%, 84%, 90%, and 97%.
How should I use SAL-T standards for calibration?
Consult your instrument's user manual to identify which calibration points are compatible with your specific analyzer model. Not all humidity values are compatible with every device model.
Can SAL-T standards be used for verification as well as calibration?
Yes, SAL-T standards can be used for both calibration and verification purposes, depending on your quality assurance requirements and device capabilities.
How are the standards supplied?
Each salt reference standard is supplied sealed in its own protective box to maintain integrity and extend shelf life.
Which Novasina instruments are compatible with SAL-T standards?
SAL-T standards are compatible with LabStart-aw, LabSwift-aw, LabTouch-aw, and LabMaster-aw NEO water activity analyzers. Compatibility varies by specific humidity value and device model.
What is the principle behind SAL-T humidity standards?
SAL-T standards utilize saturated salt solutions contained in vapor-permeable membrane plastic tablets. These solutions generate stable, reproducible humidity environments at specific relative humidity levels for accurate instrument calibration.