Stoklu siparişleriniz aynı gün kargoda!

ClimMate – Water Activity Measurement Portable Solution

Fiyat Sorunuz

Portable water activity meter with patented NOVALYTE® measurement technology and 0.01aw resolution

  • Patented NOVALYTE® measurement technology
  • Resolution: 0.01aw
  • Large sample chamber: 480ml volume
  • Portable design with battery operation (4x 1.5V alkaline or 5V DC adapter)
  • Measurement range: 0.03 to 1.00aw
  • Temperature range: 0 to 50°C (32 to 122°F)
  • Capacitive TFT display
  • USB connectivity to PC
  • IP54 protection class
  • Compact dimensions: 62 x 170 x 34mm, 0.2kg

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

ClimMate is a portable water activity measurement instrument designed for repeatable sample analysis. The large sample chamber accommodates larger sample quantities and pieces for comprehensive analysis. Featuring patented NOVALYTE® measurement technology, this battery-powered portable device serves as an excellent initial water activity (aw) measurement indicator without sample chamber temperature control or moisture equilibrium monitoring.

Technical Specifications

Measurement Principle (Water Activity) Resistive Electrolytic
Measurement Principle (Temperature) Surface-IR and NTC
Water Activity Measurement Range 0.03 to 1.00aw
Temperature Measurement Range 0 to 50°C (32 to 122°F)
Calibration Range (Water Activity) 0.11 to 0.90aw
Resolution (Water Activity) 0.01aw
Resolution (Temperature) 0.1°C
Accuracy (Water Activity) ±0.02aw within calibration range
Accuracy (Temperature) ±0.15°C
Sensitivity (Water Activity) ±0.01aw within calibration range
Sensitivity (Temperature) ±0.1°C
Repeatability (Water Activity) ±0.01aw within calibration range
Sample Chamber Volume 480ml
Sample Chamber Dimensions Diameter 80mm x Height 95mm
Power Supply Options 4x 1.5V DC alkaline batteries or 5V DC adapter
Mains Power Input 90 to 264 VAC, 50/60 Hz
Display Capacitive TFT touchscreen
Data Interface USB to PC
Housing Material Plastic enclosure
Weight 0.2kg
Dimensions (L x W x H) 62 x 170 x 34mm
Protection Class IP54
Calibration Points (% RH) Available with Nsoft-CAL only: 11%, 33%, 53%, 75%, 90%
Temperature Control in Chamber Not available
Moisture Equilibrium Monitoring Not included
21 CFR Part 11 Compliance Not compliant

Applications

  • Initial water activity (aw) measurement indicator for various sample types
  • Quality control testing in food, pharmaceutical, and chemical industries
  • Large sample analysis with oversized or particulate materials
  • Portable field and laboratory testing applications
  • Routine sample screening prior to detailed equilibrium testing
  • Battery-powered on-site measurements without external power requirements

Frequently Asked Questions

Does the ClimMate include sample chamber temperature control?
No, the ClimMate does not feature temperature control in the sample chamber. It is designed as a portable initial aw measurement indicator without environmental chamber control or moisture equilibrium monitoring capabilities.
What is the maximum sample size the ClimMate can accommodate?
The ClimMate features a large 480ml sample chamber (80mm diameter x 95mm height), allowing measurement of larger sample quantities and pieces compared to compact water activity meters.
What power options are available?
The ClimMate can operate on four 1.5V alkaline batteries or via a 5V DC adapter connected to mains power (90-264 VAC, 50/60 Hz), providing portable battery operation or stationary AC-powered use.
What makes the NOVALYTE® technology proprietary?
NOVALYTE® is a patented resistive electrolytic measurement principle that delivers 0.01aw resolution with ±0.01aw repeatability within the calibration range, enabling precise water activity determination.
How is data transferred and recorded?
The ClimMate connects to a personal computer via USB interface for data logging and analysis capabilities through compatible software.
Can calibration be performed with this device?
Calibration with multiple points (11%, 33%, 53%, 75%, 90% RH) is available when using the Nsoft-CAL calibration software and reference standards.