Stoklu siparişleriniz aynı gün kargoda!

Ion-Selective Electrodes

Fiyat Sorunuz

HACH Ion-Selective Electrodes – High-precision analytical sensors for laboratory measurements

This product is currently out of stock and unavailable.

  • Maintenance-free compact structure
  • No internal electrolyte or separate membrane required
  • Latest-generation technology with high sensitivity and extended membrane lifespan
  • Multiple socket compatibility (Fixed, BNC, and others)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Professional-grade ion-selective electrodes (ISE) featuring maintenance-free compact design, no internal electrolyte or separate membrane requirements, and latest-generation technology for superior sensitivity. Compatible with multiple socket types including Fixed and BNC connectors for versatile laboratory integration.

Technical Specifications

Na+ Selective Electrode 0.05 mg/Lt to 23 g/Lt
Br- Selective Electrode 0.4 mg/Lt to 80 g/Lt
Cl- Selective Electrode 1 mg/Lt to 35 g/Lt
CN- Selective Electrode 0.03 mg/Lt to 26 g/Lt
I- Selective Electrode 0.06 mg/Lt to 130 g/Lt
Ag2+ Selective Electrode 0.05 mg/Lt to 100 g/Lt
S2- Selective Electrode 0.03 mg/Lt to 32 g/Lt
F- Selective Electrode 0.02 mg/Lt to 20 g/Lt
Cu2+ Selective Electrode 0.5 mg/Lt to 64 g/Lt
Cd2+ Selective Electrode 0.1 mg/Lt to 11 g/Lt
Ca2+ Selective Electrode 0.04 mg/Lt to 4 g/Lt
K+ Selective Electrode 0.4 mg/Lt to 39 g/Lt
NO3+ Selective Electrode 0.4 mg/Lt to 62 g/Lt
NH4+ Selective Electrode 0.9 mg/Lt to 1.8 g/Lt
NO- Selective Electrode 0.5 mg/Lt to 460 g/Lt

Applications

  • Water quality monitoring and analysis
  • Environmental contamination assessment
  • Industrial process control and validation
  • Chemical and pharmaceutical laboratory testing
  • Food and beverage industry quality assurance
  • Research and development applications

Frequently Asked Questions

Do ion-selective electrodes require a reference electrode?
Yes. Ion-selective electrodes must always be used in combination with a reference electrode. These electrodes are fully compatible with the MM374 analytical system.
Is internal electrolyte maintenance required?
No. These ion-selective electrodes feature a sealed membrane design that eliminates the need for internal electrolyte refilling or separate membrane replacement, reducing maintenance costs and downtime.
What connector types are supported?
The electrodes support multiple socket configurations including Fixed and BNC connectors for flexible integration with various laboratory instrumentation.
What is the measurement range for chloride ions?
The Cl- selective electrode has a measurement range of 1 mg/Lt to 35 g/Lt.