Stoklu siparişleriniz aynı gün kargoda!

CO2 Incubator Model C170 — Precision Temperature & Humidity Control

Fiyat Sorunuz

Compact benchtop CO2 incubator with infrared CO2 monitoring, seamless stainless steel chamber, and stackable design for cell culture and microbiology laboratories

  • Temperature range: ambient +7°C to 50°C with ±0.1 K stability at operating point
  • Humidity control: 90–95% RH with condensation-protected humidification system
  • Automatic hot-air sterilization at 180°C
  • Infrared (IR) CO2 sensor with 0–20 vol.% measurement range
  • Venturi-effect CO2/air mixture jet for rapid, homogeneous gas mixing
  • 7-minute recovery time to 5 vol.% CO2 after 30-second door opening
  • 6-minute recovery time at 37°C after 30-second door opening
  • Seamless, deep-drawn stainless steel inner chamber resistant to corrosion
  • Tempered safety glass inner door with airtight seal
  • 3-hole stainless steel shelf for sample organization
  • Door hinged right or left (selectable at order)
  • Stackable design with optional adaptor kit
  • 3-stage 7-segment LED digital display
  • Visual and audible alarm system for troubleshooting
  • Zero-voltage alarm contact for external monitoring/integration

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The C170 is a precision-controlled CO2 incubator engineered for demanding cell culture, tissue culture, and microbiology applications. Featuring a seamless, deep-drawn stainless steel inner chamber with tempered safety glass inner door, automatic hot-air sterilization at 180°C, and condensation-protected humidification, the C170 delivers reliable performance within tight temperature and humidity tolerances. The integrated infrared CO2 sensor with Venturi-effect jet mixing ensures accurate gas control across the 0–20 vol.% CO2 range. Digital 7-segment LED display with three-stage control, visual/audible alarms, and zero-voltage alarm contact provide robust diagnostics and integration capabilities. Stackable units with adapter kit for space-efficient multi-unit deployment.

Technical Specifications

Operating Temperature Range Ambient +7°C to 50°C
Temperature Fluctuation (at 37°C) ±0.3 K
Temperature Stability (at operating setpoint) ±0.1 K
Recovery Time (37°C, door 30 sec open) 6 min
Humidity Range 90–95% RH
CO₂ Measurement Technology Infrared (IR)
CO₂ Control Range 0–20 vol.% CO₂
CO₂ Recovery Time (5 vol.%, door 30 sec open) 7 min
Hot-Air Sterilization Temperature 180°C (automatic)
Inner Chamber Material Seamless, deep-drawn stainless steel
Inner Door Material Tempered safety glass (airtight seal)
Shelf Configuration 3-hole stainless steel shelf
Display Type 3-stage 7-segment LED digital
Alarm System Visual and audible with zero-voltage contact
Door Configuration Hinged right (R) or left (L)
Nominal Power 1.1 kW
Electrical Supply (230V model) 230V 1~ 50/60 Hz, 10A fuse
Electrical Supply (120V model) 120V 1~ 60 Hz, 10A fuse
Stackable Yes, with optional adaptor kit

Applications

  • Mammalian cell culture and continuous cell lines
  • Bacterial and yeast fermentation
  • Plant tissue culture and micropropagation
  • Embryo culture and assisted reproductive technology (ART)
  • Anaerobic microbiology (with appropriate gas mixtures)
  • Fungal culture and biofilm studies
  • Insect cell culture
  • Stem cell and organoid culture
  • Quality assurance and sterility testing
  • Clinical laboratory diagnostics

Frequently Asked Questions

What is the minimum time needed for the C170 to recover to 37°C after opening the door for 30 seconds?
The recovery time is 6 minutes at 37°C setpoint after a 30-second door opening, ensuring minimal temperature deviation from your target culture condition.
How quickly does CO₂ concentration stabilize after the door is opened?
The C170 achieves 7-minute recovery time to 5 vol.% CO₂ following a 30-second door opening, thanks to the Venturi-effect gas jet and infrared sensor feedback control.
Can the C170 be stacked with other units?
Yes, the C170 supports stacking with an optional adaptor kit, allowing multi-unit deployment in space-constrained laboratories.
What sterilization method is used?
Automatic hot-air sterilization at 180°C is performed without requiring disassembly, maintaining chamber integrity and extending equipment life.
Is the chamber corrosion-resistant?
Yes, the inner chamber is constructed from seamless, deep-drawn stainless steel, offering excellent resistance to corrosive agents and long-term durability.
Can I integrate the C170 with external monitoring systems?
Yes, the zero-voltage alarm contact allows external integration with laboratory management systems, building management systems, or alarm aggregation platforms.
What CO₂ range can the C170 measure?
The infrared CO₂ sensor measures from 0–20 vol.% CO₂, covering standard culture conditions (typically 5–10 vol.%) with precise IR-based detection.
Does humidity control include condensation protection?
Yes, the condensation-protected humidification system minimizes water droplet formation, protecting culture samples and internal components from moisture-related contamination.
Can I choose door orientation?
Yes, the C170 is available with door hinged on the right (R) or left (L) at the time of order to suit your bench layout and workflow.
What is the temperature stability at the operating setpoint?
Temperature stability is ±0.1 K at operating setpoint, providing the precision required for sensitive culture applications.