Stoklu siparişleriniz aynı gün kargoda!

CO2 Incubator Mikrotest MCO (MCO² CI-80 / CI-160)

Fiyat Sorunuz

Microprocessor and PID-controlled CO2 incubator; supplied in 80 L and 160 L capacity options for cell, tissue, and bacterial culture applications.

This product is currently out of stock and unavailable.

  • Microprocessor and PID automatic control system
  • 80 L (CI-80) and 160 L (CI-160) capacity options
  • Temperature setting: Room +5 – 50°C, resolution ±0.5°C
  • CO2 range 0–20%, sensitivity ±0.1%
  • Stainless steel inner chamber, glass door, dual gas filtration
  • Over-temperature and CO2 audible-visual alarm system

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Mikrotest MCO series CO2 incubator provides stable temperature and CO2 environment for cell culture, tissue work, and bacterial propagation. The PID microprocessor control system and turbo fan-assisted homogeneous air circulation ensure precise maintenance of temperature and gas levels throughout the incubation period.

The device features an easy-to-use control panel with separate digital displays for temperature and timer settings. The stainless steel inner chamber and glass door facilitate hygiene and visual sample monitoring, while the dual gas filtration and partially heated door prevent condensation formation. Over-temperature alarm and CO2 audible-visual alarm system enhance the safety of critical culture specimens.

Available in MCO² CI-80 (80 L) and MCO² CI-160 (160 L) models for selection based on laboratory capacity; CO2 measurement accuracy can be enhanced with optional infrared sensor.

Technical Specifications

Manufacturer Mikrotest
Model MCO² CI-80 / MCO² CI-160
Usable Volume 80 L / 160 L
Power 680 W (CI-80) / 950 W (CI-160)
Temperature Setting Room +5 – 50 °C
Temperature Resolution ± 0.5 °C
Timer 0 – 999 min
CO2 Range 0 – 20 %
CO2 Sensitivity ± 0.1 %
Humidity Control CO2 + Humidity Controlled

Applications

  • Cell and tissue culture studies
  • Bacterial propagation and microbiology applications
  • Incubation tests requiring stable temperature and CO2 environment

Frequently Asked Questions

What is the difference between MCO² CI-80 and CI-160?
The primary difference is usable volume: CI-80 has 80 L capacity while CI-160 has 160 L capacity; power consumption is 680 W and 950 W respectively.
How precisely is the CO2 level controlled?
The device operates within the 0–20% CO2 range with ±0.1% sensitivity.
What is the inner chamber material?
The inner chamber is constructed of stainless steel, and the door is partially heated glass to prevent condensation formation.