  • EN12469:2000 compliant Class II design with vertical laminar airflow
  • AISI-304L epoxy powder-coated interior with AISI-316L stainless steel work surface
  • Microprocessor-based monitoring and control system
  • 2-line digital display with comprehensive status reporting
  • Integrated visual and audible alarm systems
  • Single-fan benchtop model for laboratory space optimization
  • User-friendly keypad and data logging functionality
  • Italian precision engineering and construction

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

BIOHAZARD Class II microbiological safety cabinets with vertical laminar airflow, engineered and manufactured to meet performance requirements of EN12469:2000. Features AISI-304L epoxy powder-coated internal walls with AISI-316L stainless steel working surface. Equipped with microprocessor-based monitoring system, 2-line digital display providing comprehensive status reporting, visual and audible alarms, user-friendly keypad interface, and data logging capability. Single-fan benchtop configuration with perforated safety side windows for secure installation.

Technical Specifications

Classification Class II
Standard Compliance EN12469:2000
Airflow Type Vertical laminar
Configuration Single-fan benchtop
Interior Construction AISI-304L epoxy powder-coated steel
Work Surface AISI-316L stainless steel
Control System Microprocessor-based with 2-line digital display
Alarms Visual and audible
Origin Italy

Applications

  • Microbiological research and testing
  • Clinical diagnostics and pathology
  • Pharmaceutical compounding and quality control
  • Vaccine and biological product preparation
  • Environmental monitoring and microbiology
  • Food safety and contamination testing
  • Laboratory-scale biosafety operations

Frequently Asked Questions

What is the difference between Class II safety cabinets and other classes?
Class II cabinets provide personnel, product, and environmental protection with vertical laminar airflow. They are suitable for work with agents associated with human disease and moderate hazard organisms, making them ideal for general microbiological laboratory work.
What does EN12469:2000 certification ensure?
EN12469:2000 is the European standard for microbiological safety cabinet performance. Compliance guarantees proper airflow containment, particulate filtration, air distribution uniformity, and inactivation performance to ensure safe operation.
What are the standard accessories included?
Standard accessories include: 1 vacuum outlet, 1 gas outlet with solenoid valve, 100% DEHS connection point, and 1 electrical outlet suitable for all cabinet sizes.
What monitoring capabilities does the microprocessor system provide?
The microprocessor-based system continuously monitors cabinet performance and displays comprehensive status information on a 2-line digital display. It includes visual and audible alarm alerts and data logging for regulatory compliance and troubleshooting.