Stoklu siparişleriniz aynı gün kargoda!

Behr Labor Technik E6 – 6-Sample Randall Method Oil Extraction System

Fiyat Sorunuz

Oil/solvent extraction system for simultaneous analysis of up to 6 samples using Randall methodology – 5 times faster than Soxhlet technique. Designed for food, feed, and agricultural laboratories.

  • 6-sample simultaneous extraction capacity
  • Approximately 5 times faster analysis versus Soxhlet methodology
  • 3-stage simple extraction: immersion, rinsing, drying
  • Independent filter utilization per sample chamber
  • Programmer rod adjustment—no external controller required
  • Protected design with front safety window

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Behr Labor Technik E6 is a semi-automatic oil/solvent extraction system operating via Randall extraction methodology, capable of analyzing 6 samples simultaneously. Through its simple three-stage extraction principle—immersion, rinsing, and drying—it delivers approximately 5 times faster results compared to classical Soxhlet methodology.

The system is engineered for fat determination analysis across food, feed, agriculture, cosmetics, and chemical industries. Each sample chamber utilizes independent filtration while a single control lever enables synchronized extraction of all samples. A protective front safety window enhances operator safety.

Manufactured by German-origin Behr Labor Technik, the system features programmer rod adjustment and requires no external controller. With 1000 W power consumption and 50/60 Hz frequency support, it operates across diverse electrical infrastructures. At 42 kg with compact dimensions (56×52×67 cm), the unit fits efficiently on laboratory benches.

Technical Specifications

Manufacturer Behr Labor Technik
Catalog Number B00704623
Sample Capacity 6
Package Quantity 1
Width 56 cm
Depth 52 cm
Height 67 cm
Weight 42 kg
Controller None
Adjustment Programmer rod
Frequency 50/60 Hz
Power Consumption 1000 W

Applications

  • Fat content analysis in food and beverage production
  • Fat determination in feed and agricultural products
  • Extract analysis in cosmetics and pharmaceutical industries
  • Rapid extraction testing in R&D laboratories

Frequently Asked Questions

How much faster is Randall methodology compared to Soxhlet?
Randall methodology delivers approximately 5 times faster results than classical Soxhlet extraction, achieved through its immersion-rinsing-drying sequence.
How many samples can this system process?
The Behr E6 model performs synchronized extraction on 6 samples simultaneously.
Does the system require an external controller?
No, the system does not require external controller hardware; adjustments are performed via programmer rod.