Atago PAL-Hypochlorous acid rapidly measures HOCl concentration in aqueous solutions within 50–550 ppm using just 2–3 sample drops in approximately 3 seconds. A practical field-portable device for on-site verification of disinfectant solutions.

  • Measurement range: 50–550 ppm
  • Approximately ±50 ppm accuracy
  • Results in 3 seconds, requires 2–3 sample drops
  • IP65 water/moisture-resistant housing
  • Portable operation with 2 × AAA alkaline batteries
  • Validated for aqueous HOCl solutions only

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Atago PAL-Hypochlorous acid is a digital handheld instrument designed for rapid field measurement of hypochlorous acid (HOCl) concentration in aqueous disinfectant solutions. It requires significantly less sample preparation compared to classical titration methods: only 2–3 drops of sample are needed, with results delivered in approximately 3 seconds.

The instrument operates within a 50–550 ppm measurement range with approximately ±50 ppm accuracy. This performance profile is optimized for on-site process control and quick field verification rather than precision laboratory analysis. Measurement is validated exclusively for HOCl solutions in water; applicability in alternative matrices (e.g., surfaces, food products) has not been verified.

With IP65 ingress protection, the instrument withstands humid and wet working environments. It operates on 2 × AAA alkaline batteries, enabling cordless portability. Note that the device lacks automatic temperature compensation; consistent measurements are recommended at a stable reference temperature.

For operations producing or utilizing hypochlorous acid disinfectants (food safety, sanitation, water treatment), this instrument provides a practical solution for rapid on-site HOCl concentration verification.

Technical Specifications

Model PAL-Hypochlorous acid
Catalog Number 4555
Measurement Parameter Hypochlorous Acid (HOCl) Concentration
Measurement Range 50 – 550 ppm
Accuracy Approximately ±50 ppm
Application Scope Aqueous HOCl Solutions Only
Measurement Procedure 3-Step Simple Protocol
Measurement Time Approximately 3 seconds
Sample Volume 2–3 drops
Power Source 2 × AAA Alkaline Batteries
Ingress Protection IP65
Temperature Compensation None
Manufacturer Atago

Applications

  • On-site concentration control of HOCl-based disinfectant solutions
  • Rapid verification in food safety and sanitation applications
  • Process monitoring in water treatment and disinfection systems

Frequently Asked Questions

What sample types can this instrument measure?
The instrument measures only HOCl solutions in water; applicability to alternative matrices has not been validated.
Is temperature correction required for measurements?
The device does not feature automatic temperature compensation. Consistent measurements are recommended at a stable reference temperature.
Is the accuracy level sufficient for my application?
The ±50 ppm accuracy is suited to on-site and process control applications rather than precision laboratory analysis.