Atago Master-S28M (2483) Handheld Salinity Refractometer 0-28 NaCl

Fiyat Sorunuz

Handheld refractometer with metal body and IP65 protection, measuring salinity in the 0.0-28.0% NaCl range. Ideal for rapid and practical measurement in food, water, and salt industries.

  • 0.0% - 28.0% NaCl measurement range
  • ±0.2% accuracy, 0.2% resolution
  • IP65 protection rating
  • Metal, durable housing
  • No temperature compensation; recommended for use at 10-30°C ambient temperature
  • Measurement with just 2-3 sample drops

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Atago Master-S28M is a handheld refractometer with a metal body and IP65 protection rating, designed for measuring salt concentration in the 0.0-28.0% NaCl range. Delivering fast results with just 2-3 sample drops, it provides a practical solution for both laboratory and field applications.

As the device does not feature automatic temperature compensation, measurements should be conducted within an ambient temperature range of 10-30°C for optimal accuracy. With ±0.2% accuracy and 0.2% resolution, it delivers consistent results for salinity analysis across diverse applications. The metal housing and IP65 protection rating ensure robust performance in humid or challenging field environments.

Applications range from food quality control to water treatment and aquarium monitoring, making it suitable for any operation requiring salinity tracking.

Technical Specifications

Manufacturer Atago
Model Master-S28M
Catalog Number 2483
Measurement Scale Salt (NaCl)
Measurement Range 0.0% – 28.0% NaCl
Accuracy ±0.2%
Resolution 0.2%
Temperature Compensation None
Ambient Temperature 10-30°C
IP Protection Rating IP65
Housing Metal
Dimensions 32(W) x 34(D) x 168(H) mm
Weight 130g

Applications

  • Salinity measurement in water and salt industry applications
  • Quality control in food laboratories
  • Water quality monitoring in marine and aquarium settings

Frequently Asked Questions

Does the device include automatic temperature compensation?
No, the Master-S28M does not feature automatic temperature compensation. For the most accurate results, measurements should be taken at ambient temperatures between 10-30°C.
How much sample is required for measurement?
A sample volume of 2-3 drops dispensed onto the prism surface is sufficient for measurement.
Can the device be used in challenging field conditions?
Yes, the IP65 protection rating and metal housing ensure durability and reliable performance in humid and demanding field environments.