Multi-wavelength Abbe refractometer measuring refractive index and Abbe number across 450-1550nm wavelength range with 1550nm support for telecom and fiber optic applications.

  • Measurement capability across 450-1550 nm wavelength range
  • 1550nm support for telecom and fiber optic applications
  • 1550nm refractive index measurement range: 1.2662 - 1.6759
  • Abbe number (νd or νe) measurement capability
  • Atago manufacturer, Catalog No: 1412
  • No IP65 protection and no temperature compensation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The DR-M2/1550 is a Multi-Wavelength Abbe Refractometer capable of measuring refractive index and Abbe number across an extended wavelength range from 450nm to 1550nm. Beyond standard visible region measurements, it enables characterization of fiber optic and telecom components at 1550nm, making it suitable for optical material development, fiber optic manufacturing, and telecommunication R&D laboratories. The instrument provides broader spectral coverage than the standard DR-M2 model; 1550nm measurement is not supported in the standard version. The refractive index measurement range varies by wavelength; at 1550nm, the measurement range is 1.2662-1.6759. The instrument lacks IP65 protection and temperature compensation; therefore, a controlled measurement environment is recommended.

Technical Specifications

Manufacturer Atago
Model DR-M2/1550
Wavelength Range 450-1550 nm
1550nm Refractive Index Range 1.2662 – 1.6759
Telecom Fiber Optic Support Yes (1550nm)
IP65 Protection No
Temperature Compensation No
Catalog No 1412
Price €22,000

Applications

  • Refractive index measurement of fiber optic cables and telecom components
  • Near-infrared optical material characterization
  • Optical glass and polymer R&D studies

Frequently Asked Questions

How does the DR-M2/1550 differ from the standard DR-M2 model?
The DR-M2/1550 supports wavelength measurement up to 1550nm and enables telecom and fiber optic measurements; this range is not supported in the standard model.
Does the instrument include temperature compensation?
No, the DR-M2/1550 does not feature temperature compensation; therefore, the measurement environment temperature must be controlled.
Is IP65 protection rating available?
No, the instrument does not have IP65 protection rating.