Stoklu siparişleriniz aynı gün kargoda!

Atago CM-ISα-PG In-line Propylene Glycol Monitor

Fiyat Sorunuz

Atago CM-800α based in-line refractometer for continuous monitoring of propylene glycol concentration and refractive index. Used in food-safe cooling systems.

  • PG measurement range: 0.0-90.0%
  • Accuracy ±0.4%, resolution 0.1%
  • RI measurement range 1.32000-1.49100
  • RS-232C / 4-20mA output
  • ATEX/IECEx certified
  • No IP65 protection or temperature compensation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The CM-ISα-PG is an Atago model configured on the CM-800α in-line refractometer platform for real-time monitoring of propylene glycol (PG) solution concentration and refractive index. Via RS-232C and 4-20mA outputs, it integrates directly into process control systems or PLC/SCADA infrastructure. ATEX/IECEx certification indicates suitability for use in facilities with explosive atmosphere risk. It performs measurements within the 0.0-90.0% PG range with ±0.4% accuracy and 0.1% resolution; refractive index measurement range is 1.32000-1.49100. Temperature compensation and IP65 protection are not featured in this model, therefore controlled environmental conditions or external temperature correction should be considered for applications requiring these functions. Suitable for concentration monitoring of PG-based antifreeze solutions in food processing, beverage production, and cooling circuit applications.

Technical Specifications

Manufacturer Atago
Platform CM-800α
PG Range 0.0-90.0%
Accuracy ±0.4%
Resolution 0.1%
RI Range 1.32000-1.49100
Output RS-232C, 4-20mA
Certification ATEX/IECEx
IP Protection No IP65 Protection
Temperature Compensation Not Available

Applications

  • PG concentration monitoring in food processing cooling circuits
  • Process control in beverage production lines
  • Industrial cooling systems requiring Ex-zone compliance

Frequently Asked Questions

Does the instrument perform temperature compensation?
No, this model does not feature temperature compensation; maintaining controlled measurement temperature or applying external compensation is recommended.
Does it have IP65 protection?
No, this model does not have IP65 protection; additional protection may be required in wet or dusty environments.
What outputs are supported?
RS-232C and 4-20mA outputs enable integration with process control systems.