Stoklu siparişleriniz aynı gün kargoda!

12.88 mS/cm (12,880 µS/cm) Conductivity Standard Calibration Solution APERA

Fiyat Sorunuz

NIST-certified conductivity calibration standard for laboratory conductivity meters

  • Standardized against NIST-certified reference standards at 25°C (77°F)
  • Suitable for calibration of all conductivity meter types
  • Dual-sealed container with 1-year shelf life
  • Temperature and conductivity reference table included on label
  • Non-hazardous product (MSDS available for download)
  • Temperature-compensated reference values provided

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Apera Instruments 12.88 mS/cm Conductivity Standard Calibration Solution is manufactured from ultra-high purity chemicals and standardized against NIST-traceable reference standards at 25°C (77°F). This reference solution is ideal for calibration of all types of conductivity meters and probes. Since conductivity values are temperature-dependent, a temperature/conductivity reference table is provided on the bottle label for accurate reference. All solutions feature dual-seal bottles, are not subject to DOT shipping restrictions, and maintain a 1-year shelf life with expiration date printed on the container.

Technical Specifications

Conductivity Value 12.88 mS/cm (12,880 µS/cm) at 25°C
Reference Temperature 25°C (77°F)
Container Type Dual-sealed bottle
Shelf Life 1 year from manufacture date
Hazard Classification Non-hazardous
Shipping Restrictions Not subject to DOT regulations
Certification NIST-traceable reference standards

Applications

  • Calibration of benchtop conductivity meters
  • Field portable conductivity probe calibration
  • Laboratory quality assurance and validation procedures
  • Multi-point calibration protocols in water analysis
  • Verification of conductivity sensor accuracy
  • Industrial process monitoring and control

Frequently Asked Questions

Why is temperature control important for conductivity calibration?
Conductivity is highly temperature-dependent. This solution is standardized at 25°C, and a temperature/conductivity reference table is provided to account for variations at different temperatures. Always calibrate near the reference temperature or apply appropriate temperature corrections.
How should this calibration solution be stored?
Store at room temperature away from direct sunlight. Keep the bottle tightly sealed when not in use. Do not expose to extreme temperatures. Store out of reach of children. Refer to expiration date on the label.
Is this product safe to handle?
Yes, this is a non-hazardous product. Safety Data Sheet (MSDS) is available for download and provides complete handling information.
Can this solution be used for all conductivity meter types?
Yes, this 12.88 mS/cm standard is suitable for calibrating all types of conductivity meters and sensors, whether laboratory or field-based instruments.
What does the dual-seal bottle protect against?
The dual-seal design provides superior protection against evaporation and contamination, ensuring solution stability throughout the 1-year shelf life.
Is this solution subject to shipping regulations?
No, this non-hazardous solution is not subject to DOT shipping restrictions, simplifying transportation and storage requirements.