Stoklu siparişleriniz aynı gün kargoda!

Apera 2310T-F Plastic Conductivity Electrode

Fiyat Sorunuz

High-range conductivity and temperature electrode with platinum-black coated sensor ring, cell constant K=10.0, up to 2,000 µS/cm

  • Platinum-black coated sensor ring for superior stability in high-range applications
  • High accuracy: ±1.5% FS (±10% FS without calibration)
  • Built-in temperature sensor with automatic temperature compensation
  • Cell constant K=10.0 optimized for high-ionic solutions
  • 1 m cable length with BNC/RCA connector
  • Compatible with Apera EC800, EC820, PC800, PC820, and EC700 meters

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Professional-grade conductivity electrode designed for high-range conductivity measurement up to 2,000 µS/cm with cell constant K=10.0. Features a unique platinum-black coated sensor ring that provides stable and accurate measurement across high conductivity ranges. Built-in temperature sensor enables automatic temperature compensation. Delivers accuracy of ±1.5% FS; maintains ±10% FS accuracy even without calibration. 1 m cable with BNC/RCA connector.

Technical Specifications

Measurement Range 0-2,000 µS/cm
Cell Constant K=10.0
Temperature Compensation Automatic
Cable Length 1 m
Connector Type BNC/RCA
Sensor Coating Platinum-black

Applications

  • Industrial wastewater and process water analysis
  • Seawater and brine conductivity monitoring
  • Chemical manufacturing and process control
  • Highly concentrated ionic solution measurement
  • Environmental and drinking water quality testing
  • Pharmaceutical and laboratory applications

Frequently Asked Questions

What does the cell constant K=10.0 indicate?
The cell constant determines the electrode's measurement range capability. K=10.0 is specifically designed for high-range conductivity measurements up to 2,000 µS/cm, making it suitable for concentrated solutions.
Is calibration necessary for accurate measurements?
With calibration, the electrode achieves ±1.5% FS accuracy. Without calibration, accuracy remains at ±10% FS, making it suitable for many field applications where precision calibration is not immediately available.
Which Apera meters are compatible with this electrode?
This electrode is compatible with Apera meters: EC800, EC820, PC800, PC820, and EC700.
What is the advantage of the platinum-black coating?
The platinum-black coating provides enhanced stability and durability in high-range conductivity measurements, ensuring consistent and reliable readings over extended use periods.