Stoklu siparişleriniz aynı gün kargoda!

Total Aflatoxin IAC SENSIPure

Fiyat Sorunuz

Immunoaffinity column for total aflatoxin measurement in 3 mL format, enabling precise sample purification and cleanup with monoclonal antibody specificity

  • Comprehensive quality control
  • QC tests with matrix-containing samples
  • High specificity purification with monoclonal antibodies
  • Broad application range for various matrices
  • Validated matrices: grains, tree nuts, dried fruits, spices, and animal feed
  • Robust and stable performance
  • 3 mL format compatible with liquid handling automation systems
  • Excellent flow characteristics

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Total Aflatoxin IAC SENSIPure is an immunoaffinity column designed for the purification and cleanup of sample extracts to achieve specific, sensitive, and equipment-precise measurements of total aflatoxin. Sample extracts are diluted and applied to the column where monoclonal antibodies specifically bind aflatoxin toxins. A washing step removes interfering matrix components. Aflatoxins are then eluted from the column using organic solvent. After dilution, the extract is ready for instrumental measurement.

Technical Specifications

SKU IAAFT50
Analysis Principle Immunoaffinity column for total aflatoxin
Format 50 columns, 3 mL each
Maximum Column Capacity > 500 ng
Cross-Reactivities Aflatoxin B1: 100%; Aflatoxin B2: > 90%; Aflatoxin G1: > 90%; Aflatoxin G2: > 90%

Applications

  • Food safety testing for aflatoxin contamination
  • Feed quality control and verification
  • Grain and cereal analysis
  • Tree nut and dried fruit testing
  • Spice and seasoning quality assurance
  • Pre-analytical sample cleanup for HPLC and LC-MS/MS

Frequently Asked Questions

What is the purpose of the IAC SENSIPure column?
The IAC SENSIPure column is used for sample preparation and cleanup to remove matrix interferents before total aflatoxin analysis, ensuring accurate and reliable results with high specificity.
How many samples can be processed with one kit?
Each kit contains 50 columns (3 mL format each), allowing processing of up to 50 samples depending on dilution factors and sample volume requirements.
What matrices are validated for this product?
Validated matrices include grains, tree nuts, dried fruits, spices, and animal feed. The broad application range allows use with other similar matrices.
Is this product compatible with automation systems?
Yes, the 3 mL format is specifically designed to be compatible with liquid handling automation systems for high-throughput sample processing.
What are cross-reactivities and why are they important?
Cross-reactivities indicate how well the monoclonal antibodies bind to different aflatoxin congeners. High cross-reactivities (>90%) ensure the column captures all major aflatoxin types for total aflatoxin measurement.