Stoklu siparişleriniz aynı gün kargoda!

Immunoaffinity Columns IAC Zearalenone (BBI Solutions)

Fiyat Sorunuz

Immunoaffinity clean-up column for zearalenone analysis. A reliable solution with high recovery and cross-reactivity data for laboratories performing sample clean-up prior to HPLC-FLD.

This product is currently out of stock and unavailable.

  • Working range: 5–500 ng zearalenone per IAC
  • Recovery rate: 85%
  • Column capacity: 2.7 µg zearalenone
  • Blank contamination level: <5 ng (HPLC-FLD detection limit)
  • Cross-reactivity: Zearalenone 100%, Zearalenol 97%, Zearalenol 86%, Zearalanol 99%, Zearalanol 94%
  • Package options: 10/30/50/100 columns, 3 ml column volume

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Immunoaffinity Columns IAC Zearalenone are used for sample clean-up (clean-up) prior to accurate determination of zearalenone levels in cereal, feed, and food samples by HPLC-FLD. These columns, manufactured by BBI Solutions, are the preferred choice in mycotoxin analysis laboratories for routine and accredited testing procedures.

The column is effective in a working range of 5–500 ng zearalenone per IAC and provides an 85% recovery rate. While demonstrating 100% specificity for zearalenone, it also provides high cross-reactivity to zearalanol and zearalenol derivatives, enabling detection of related metabolites. With a 3 ml column volume, it is compatible with standard HPLC preparation workflows.

The product is offered in package options of 10, 30, 50, and 100 columns; the appropriate package can be selected according to the laboratory's sample volume.

Technical Specifications

Manufacturer BBI Solutions
Mycotoxin Type Zearalenone
Column Volume 3 ml
Working Range 5–500 ng Zearalenone / IAC
Recovery Rate 85%
Column Capacity 2.7 µg Zearalenone
Blank Contamination <5 ng (HPLC-FLD detection limit)
Package Options 10 columns (BTZE315005), 30 columns (BTZE315030), 50 columns (BTZE315050), 100 columns (BTZE315100)

Applications

  • Sample clean-up prior to zearalenone analysis in cereal and feed samples
  • Food safety laboratories performing mycotoxin residue analysis by HPLC-FLD
  • Studies requiring concurrent evaluation of zearalenone metabolites (zearalenol, zearalanol)

Frequently Asked Questions

Which analytical method are these columns used with?
The columns are designed for sample clean-up prior to HPLC-FLD; the detection limit is specified as <5 ng.
What is the working range of the column?
It is effective in the range of 5–500 ng zearalenone per IAC, with a capacity of 2.7 µg.
Does the column detect only zearalenone?
No, in addition to zearalenone, the column demonstrates high cross-reactivity to zearalanol and zearalenol derivatives.