Stoklu siparişleriniz aynı gün kargoda!

BIOTEZ IAC Ochratoxin Immunoaffinity Columns (3ml)

Fiyat Sorunuz

Immunoaffinity cleanup column for ochratoxin analysis. Delivers high recovery and low contamination in sample preparation with HPLC-FLD methodology.

This product is currently out of stock and unavailable.

  • Working range: 0.04-200 ng Ochratoxin per IAC column
  • Zero contamination threshold: <0.04 ng (HPLC-FLD detection limit)
  • Recovery rate: 85±5%
  • Column capacity: 3 µg Ochratoxin
  • Cross-reactivity: Ochratoxin A 100%, Ochratoxin B 103%
  • Package options: 10/30/50/100 columns (3ml each)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

BIOTEZ IAC Ochratoxin columns are immunoaffinity-based cleanup columns designed for sample preparation prior to ochratoxin analysis in food and agricultural products. With HPLC-FLD compatible working range and superior recovery rates, these columns provide reliable pre-analytical solution for mycotoxin testing laboratories.

The columns enable ochratoxin quantification in the 0.04-200 ng range and deliver consistent results with 85±5% recovery rate. Specific binding is ensured with 100% cross-reactivity for Ochratoxin A and 103% for Ochratoxin B. With 3ml column volume and 3 µg binding capacity, the columns accommodate various sample matrices. Manufactured by BBI Solutions, these columns are recommended for routine and research-based ochratoxin analysis in laboratory settings.

Flexible procurement options available in multiple package configurations (10, 30, 50, 100 columns) to meet laboratory throughput requirements.

Technical Specifications

Mycotoxin Type Ochratoxin
Column Volume 3 ml
Working Range 0.04-200 ng Ochratoxin
Zero Contamination <0.04 ng (HPLC-FLD detection limit)
Recovery Rate 85±5%
Column Capacity 3 µg Ochratoxin
Cross-Reactivity Ochratoxin A 100%, Ochratoxin B 103%
Manufacturer BBI Solutions
Package Options 10 columns (BTOT312005), 30 columns (BTOT312030), 50 columns (BTOT312050), 100 columns (BTOT312100)

Applications

  • Sample cleanup prior to ochratoxin analysis in food and agricultural products
  • Mycotoxin residue analysis by HPLC-FLD
  • Routine food safety laboratory testing

Frequently Asked Questions

Which analytical method is this column designed for?
The column is specifically designed for sample cleanup prior to ochratoxin analysis using HPLC-FLD methodology.
What is the recovery rate?
The column recovery rate is specified as 85±5%.
What package sizes are available?
Columns are supplied in 10, 30, 50, and 100 column packs, each containing 3ml column volume.