BBI IAC Combi Deoxynivalenol + Zearalenone Immunoaffinity Column

Fiyat Sorunuz

Immunoaffinity column for simultaneous cleanup of DON and Zearalenone mycotoxins in a single cartridge. Sample preparation for HPLC-FLD/HPLC-MS analysis.

This product is currently out of stock and unavailable.

  • Working range: 5–500 ng DON+ZEA per IAC cartridge
  • Recovery rate: >85%
  • Column capacity: 1.8µg DON / 2.7µg ZEA
  • Blank contamination limit: <5ng (HPLC-FLD detection limit)
  • 3ml column volume, package options for 10/30/50/100 cartridges
  • Cross-reactivity data available for DON and ZEA

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

This immunoaffinity column manufactured by BBI Solutions is engineered to extract Deoxynivalenol (DON) and Zearalenone (ZEA) mycotoxins from grain and food samples in a single-step process. A practical solution for food and feed laboratories equipped with HPLC-FLD or HPLC-MS systems.

The column operates within a 5–500 ng working range and delivers recovery rates exceeding 85% for both toxins. With a column capacity of 1.8µg for DON and 2.7µg for Zearalenone, it is well-suited for routine sample loads. Cross-reactivity data are provided, indicating the extent to which related mycotoxin metabolites (Nivalenol, Acetyl-DON derivatives, Zearalanols/Zearalenol isomers) are detected, which is important for result interpretation.

With a 3ml column volume and package options of 10, 30, 50, and 100 cartridges, supply flexibility is provided to accommodate different laboratory capacities.

Technical Specifications

Manufacturer BBI Solutions
Mycotoxin Type Deoxynivalenol + Zearalenone
Column Volume 3ml
Working Range 5–500 ng (per IAC cartridge)
Recovery Rate >85%
Column Capacity 1.8µg DON, 2.7µg ZEA
Blank Contamination Limit <5ng (HPLC-FLD detection limit)
Package Options 10 (BTCD323005), 30 (BTCD323030), 50 (BTCD323050), 100 (BTCD323100) cartridges

Applications

  • Multi-mycotoxin analysis of DON+ZEA in grains and grain products
  • Sample cleanup prior to HPLC-FLD or HPLC-MS analysis
  • Routine testing in feed and food safety laboratories

Frequently Asked Questions

Which mycotoxins does this column clean up simultaneously?
It simultaneously removes Deoxynivalenol (DON) and Zearalenone (ZEA) mycotoxins in a single cartridge.
What is the recovery rate of the column?
It provides recovery rates exceeding 85% for both toxins.
What package sizes are available?