Stoklu siparişleriniz aynı gün kargoda!

Hand-Held Refractometer Measuring Salinity 0-10 NaCl Atago 2473 Master-S10M

Fiyat Sorunuz

Atago Master-S10M, a metal-body hand-held refractometer for rapid salinity measurement in the 0.0%-10.0% NaCl range. Analysis is performed with 2-3 drops of sample, no automatic temperature compensation.

  • 0.0% - 10.0% NaCl measurement range
  • ±0.2% accuracy, 0.2% resolution
  • Metal, durable body construction
  • Rapid measurement with 2-3 sample drops
  • Operating temperature 10-30°C ambient
  • No temperature compensation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Atago 2473 Master-S10M is a hand-held optical refractometer designed for applications requiring low-concentration salinity measurement. It measures in the 0.0% – 10.0% NaCl range and delivers quick results with just 2-3 drops of sample.

The metal body structure provides durable performance in field and laboratory environments. As the instrument does not feature automatic temperature compensation, the most accurate results are obtained when measurements are taken within an ambient temperature range of 10-30°C. With ±0.2% accuracy and 0.2% resolution, it provides reliable control for low-concentration specimens such as water, food, and seawater salinity analysis.

Electricity-free and battery-free optical design ensures practical field operation. Its compact size and 130g weight offer excellent portability.

Technical Specifications

Manufacturer Atago
Model Master-S10M
Catalog No. 2473
Measurement Scale Sodium Chloride (NaCl)
Measurement Range 0.0% – 10.0% NaCl
Measurement Accuracy ±0.2%
Resolution 0.2%
Temperature Compensation None
Operating Temperature 10-30°C
IP Rating Not rated (not IP65)
Body Material Metal
Dimensions 3.2 x 3.4 x 16.8 cm
Weight 130g

Applications

  • Salinity control in water and salt industries
  • Quality control analysis in food laboratories
  • Marine and aquarium water quality monitoring

Frequently Asked Questions

Does the Master-S10M have temperature compensation?
No, the instrument does not have automatic temperature compensation. For accurate results, measurements should be performed at an ambient temperature of 10-30°C.
How much sample is required for measurement?
Only 2-3 drops of sample are sufficient for measurement.
Is this instrument suitable for high-concentration salt solutions?
No, the instrument measures in the 0.0%-10.0% NaCl range; a different model is required for higher concentrations.