NucleoCounter® YC-100™ IQ/OQ Test Kit

Fiyat Sorunuz

Installation and Operational Qualification test kit for NucleoCounter® YC-100™ with fluorescent reference beads and comprehensive OQ test plan

  • Complete IQ/OQ validation kit for NucleoCounter® YC-100™
  • Fluorescent reference beads for functional verification
  • Blank control vial for baseline measurement reference
  • Comprehensive OQ test plan with detailed procedures
  • Validates installation assembly and operational specifications

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The NucleoCounter® YC-100™ test kit comprises one vial containing fluorescent beads, one blank vial without beads for reference control, and an OQ test plan with detailed information on device qualification procedures. Designed for complete Installation Qualification (IQ) and Operational Qualification (OQ) verification of the NucleoCounter® YC-100™ system.

Technical Specifications

Kit Components 1 vial with fluorescent beads, 1 blank vial (without beads), 1 OQ test plan
Application Installation Qualification (IQ) and Operational Qualification (OQ)
Purpose Device installation verification and functional performance validation

Applications

  • Installation Qualification (IQ) – documenting correct device delivery and installation per manufacturer requirements
  • Equipment performance validation and compliance verification
  • Regulatory documentation and audit support
  • Pre-use system suitability testing

Frequently Asked Questions

What is Installation Qualification (IQ)?
IQ is documented evidence that the NucleoCounter® YC-100™ has been delivered and installed correctly in accordance with manufacturer specifications and assembly requirements.
What is Operational Qualification (OQ)?
OQ is a systematic test process that confirms the device's functionality operates within the manufacturer's specified performance parameters and acceptance criteria.
What are the components included?
The kit includes one vial containing fluorescent reference beads, one blank vial without beads for control purposes, and a detailed OQ test plan with all necessary procedures.
What is the purpose of the blank vial?
The blank vial without beads serves as a negative control reference to establish baseline measurements and verify device functionality accuracy.