NucleoCounter® NC-100™ IQ/OQ Test Kit with Fluorescent Reference Beads

Fiyat Sorunuz

Comprehensive Installation and Operational Qualification kit for NucleoCounter® NC-100™ automated cell counter with four fluorescent bead reference standards.

  • 4 vials with fluorescent bead standards at different concentrations
  • Validates Installation Qualification (IQ) and Operational Qualification (OQ)
  • Includes comprehensive IQ/OQ test plan and procedures
  • Confirms device setup and installation accuracy
  • Verifies operational functionality against manufacturer specifications
  • Delivers documented evidence of device performance compliance

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The NucleoCounter® NC-100™ IQ/OQ Test Kit is designed to validate the Installation Qualification (IQ) and Operational Qualification (OQ) of the NucleoCounter® NC-100™ device. The kit contains 4 vials of fluorescent reference beads at different concentrations, enabling comprehensive verification of device functionality and performance according to manufacturer specifications. The kit includes detailed IQ/OQ test protocols to be executed on the instrument.

Technical Specifications

Compatibility NucleoCounter® NC-100™
Application Installation Qualification (IQ) and Operational Qualification (OQ)
Documentation Includes IQ/OQ test plan and test protocols

Applications

  • Initial instrument qualification following installation
  • Verification of device setup and installation integrity
  • Operational performance validation against specifications
  • GMP/regulatory compliance documentation
  • Periodic device qualification revalidation
  • Equipment maintenance and performance verification

Frequently Asked Questions

What is Installation Qualification (IQ)?
IQ is documented proof that the NucleoCounter® NC-100™ device has been delivered and installed in accordance with manufacturer-specified requirements and operational standards.
What is Operational Qualification (OQ)?
OQ is a testing procedure that verifies the device's functionality and performance conform to the manufacturer's provided specifications and acceptance criteria.
Why is IQ/OQ testing necessary?
IQ/OQ testing provides documented evidence that the instrument is properly installed and functioning according to specifications, ensuring data integrity and regulatory compliance.
How are the fluorescent reference beads used?
The four vials containing fluorescent beads at different concentrations serve as reference standards to validate the detection capabilities and counting accuracy of the NC-100™ device.