Stoklu siparişleriniz aynı gün kargoda!

Pag Laboratory Perchloric Acid Fume Hood

Fiyat Sorunuz

Fume hood with specialized acid-resistant drainage system and filtration designed for safe exhaust of perchloric acid (HClO4) vapors. Engineered for R&D and analytical laboratories.

  • AISI 304/316 stainless steel acid-resistant interior surface
  • Integrated acid-resistant drainage system
  • Specialized filter unit for perchloric acid vapors
  • Adjustable 12-20 ACH airflow rate
  • Digital airflow and filter condition indicator
  • Heat-resistant LED interior illumination

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Perchloric Acid Fume Hood is a ventilation system specifically engineered to mitigate corrosion and accumulation risks posed by HClO4 vapors. Unlike standard laboratory fume hoods, it integrates an acid-resistant drainage system that prevents vapor condensation and hazardous residue buildup within the ducting.

The interior surface features AISI 304/316 stainless steel cladding, providing long-term durability against corrosive vapors, while a specialized perchloric acid vapor filter unit ensures effective vapor containment. The adjustable 12-20 ACH (air changes per hour) airflow rate allows optimization of ventilation capacity according to varying operational intensities and chemical concentrations.

The digital control panel provides real-time monitoring of airflow and filter integrity, ensuring operational safety for laboratory personnel. Heat-resistant LED interior illumination maintains optimal workspace visibility during extended operations. For laboratories working with perchloric acid, this specialized fume hood system is essential compared to standard models, protecting both personnel safety and equipment longevity.

Technical Specifications

Manufacturer Pag Laboratory
Material Stainless Steel AISI 304 / 316
Air Change Rate (ACH) 12-20 times/hour (adjustable option available)
Drainage System Integrated and acid-resistant
Dimensions (Example) 120 x 90 x 220 cm (W x D x H)
Filtration Specialized filter unit for perchloric acid vapors
Power Consumption 100-240V, 50/60Hz
Illumination LED interior lighting, heat-resistant
Control Panel Digital airflow and filter condition display

Applications

  • Analytical procedures and sample preparation operations involving perchloric acid (HClO4)
  • R&D laboratories requiring controlled handling of strong oxidizing acid vapors
  • Environments where equipment and personnel protection against corrosive chemical vapor exposure is critical

Frequently Asked Questions

Why should a perchloric acid fume hood be used instead of a standard fume hood?
Standard laboratory fume hoods cannot prevent perchloric acid vapors from condensing and accumulating within the ducting system; this specialized system eliminates that risk through integrated acid-resistant drainage and customized filtration.
How is the air change rate adjusted?
The 12-20 ACH range can be adjusted optionally based on laboratory operational intensity and vapor concentration requirements.
How is filter condition monitored?
The digital control panel provides real-time monitoring of airflow and filter status.