Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-47S Ferric Chloride (FeCl₃) Refractometer

Fiyat Sorunuz

Digital handheld refractometer for rapid and precise measurement of ferric chloride (FeCl₃) solution concentration in the range of 0.0–15.0%. Suitable for water treatment facilities and PCB manufacturing processes.

  • FeCl₃ measurement range: 0.0–15.0%, resolution 0.1%
  • Accuracy ±0.2% FeCl₃, ±1°C temperature
  • Simultaneous temperature measurement: 10.0–40.0°C, 0.1°C resolution
  • Measurement with only 2–3 sample drops
  • IP65-rated metal housing
  • No temperature compensation – results must be evaluated accordingly

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-47S is a digital handheld refractometer specifically designed to measure the concentration of ferric chloride (FeCl₃) aqueous solutions. It provides a practical solution for operators performing coagulant control in water treatment plants and monitoring etching baths in PCB manufacturing.

The instrument measures FeCl₃ concentration in the range of 0.0–15.0% with an accuracy of ±0.2% using only 2–3 sample drops; simultaneously, it displays temperature within the range of 10.0–40.0°C with 0.1°C resolution. Thanks to its metal housing and IP65 protection rating, it delivers rugged performance in field and plant environments. It provides results significantly faster than classical titration analysis methods and requires no complex chemical procedures.

Important note: This instrument does not feature automatic temperature compensation; therefore, measurement results must be evaluated taking the sample temperature into account.

Technical Specifications

Manufacturer Atago
Model PAL-47S
Catalog Number 4447
Measurement Scale Ferric Chloride (g/100g) + Temperature
FeCl₃ Range 0.0 – 15.0%
FeCl₃ Resolution 0.1%
FeCl₃ Accuracy ±0.2%
Temperature Range 10.0 – 40.0°C
Temperature Resolution 0.1°C
Temperature Accuracy ±1°C
Sample Volume 2–3 drops
IP Rating IP65
Temperature Compensation None
Housing Metal

Applications

  • Ferric chloride coagulant concentration control in water treatment facilities
  • Ferric chloride etching bath monitoring in PCB manufacturing
  • Iron(III) chloride solution quality control in chemical industries

Frequently Asked Questions

How much sample is required for measurement with the PAL-47S?
Only 2–3 drops of sample are required.
Does this instrument have temperature compensation?
No, the PAL-47S does not feature automatic temperature compensation; results must be evaluated taking the sample temperature into account.
What environmental conditions can this instrument withstand?
With its IP65 protection rating and metal housing, it can be safely used in plant and field environments.