Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-44S Lithium Chloride Refractometer

Fiyat Sorunuz

Digital handheld refractometer measuring lithium chloride (LiCl) concentration in aqueous solutions. 0-20.0% LiCl range, simultaneous temperature measurement, and rapid results from 2-3 sample drops. Suitable for battery electrolyte production and chemistry laboratories.

  • LiCl measurement range: 0.0-20.0%, resolution 0.1%
  • LiCl accuracy: ±0.2%
  • Simultaneous temperature measurement: 10.0-40.0°C, ±1°C accuracy
  • Sample volume: only 2-3 drops
  • IP65 protection rating
  • No automatic temperature compensation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

Atago PAL-44S is a digital handheld refractometer designed to measure lithium chloride (LiCl) solution concentration. It provides a practical solution for battery raw material production, concentration control in chemical processes, and laboratory analysis applications.

The instrument measures within the 0.0-20.0% LiCl range with 0.1% resolution and ±0.2% accuracy. It simultaneously provides temperature readout in the 10.0-40.0°C range with ±1°C accuracy. Measurement is possible using only 2-3 sample drops, providing significant time savings compared to conventional titration methods. The IP65 protection rating enables use in humid and dusty production environments.

Note that the instrument does not feature automatic temperature compensation; therefore, result evaluation may be necessary depending on measurement conditions. The measurement scale is calibrated specifically for LiCl (g/100g), so use with different solution types is not recommended.

Technical Specifications

Model PAL-44S
Catalog Number 4444
Manufacturer Atago
Measurement Scale Lithium Chloride (g/100g) + Temperature
LiCl Measurement Range 0.0 – 20.0%
LiCl Resolution 0.1%
LiCl Accuracy ±0.2%
Temperature Range 10.0 – 40.0°C
Temperature Resolution 0.1°C
Temperature Accuracy ±1°C
Sample Volume 2-3 drops
IP Protection Class IP65
Temperature Compensation None
General Brix Resolution 0.1 Brix

Applications

  • Concentration control in lithium chloride-based battery electrolyte manufacturing
  • Lithium chloride solution monitoring in chemical production processes
  • Lithium chloride analysis in research laboratories

Frequently Asked Questions

Which solutions can the PAL-44S be used with?
The instrument is calibrated specifically for lithium chloride (LiCl) aqueous solutions and will not provide accurate results with other solution types.
How much sample is required for measurement?
Measurement can be performed with only 2-3 sample drops.
Does the instrument have automatic temperature compensation?
No, the PAL-44S does not feature automatic temperature compensation.