Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-48S Strontium Chloride Refractometer

Fiyat Sorunuz

Digital handheld refractometer measuring SrCl₂ solution concentration in the range %0.0-25.0 with ±0.2% accuracy in 3 seconds. Designed for quality control in ceramics, glass, and specialty chemical production.

  • SrCl₂ measurement range: %0.0-25.0 (g/100g)
  • Accuracy: ±0.2% SrCl₂, ±1°C temperature
  • Resolution: 0.1 Brix
  • Measurement time: ~3 seconds, sample volume 2-3 drops
  • IP65 water resistance protection
  • Compact and lightweight: 5.5×3.1×10.9 cm, 100g

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-48S is a digital handheld refractometer specifically calibrated for rapid and precise measurement of strontium chloride (SrCl₂) concentration in aqueous solutions. It provides a practical field/laboratory solution for those requiring accurate SrCl₂ ratio monitoring in ceramic manufacturing, glass production, and specialty chemical processes.

The instrument delivers results in approximately 3 seconds using just 2-3 sample drops. ATAGO's optical measurement system provides repeatable data with 0.1% resolution and ±0.2% SrCl₂ accuracy. With IP65 protection rating, it can be safely used in manufacturing environments containing water and dust. Its compact 100-gram body and AAA battery operation make it portable and suitable for field deployment.

As the device lacks automatic temperature compensation, measurements should be taken within the 10-40°C operating temperature range. With these characteristics, the PAL-48S is a reliable and practical alternative for rapid quality control requirements outside the laboratory.

Technical Specifications

Manufacturer Atago
Model PAL-48S
Measurement Range SrCl₂: %0.0-25.0 (g/100g); Temperature: 10.0-40.0°C
Resolution 0.1 Brix
Accuracy ±0.2% SrCl₂, ±1°C Temperature
Operating Temperature 10-40°C Ambient
Measurement Time Approximately 3 seconds
Sample Volume 2-3 drops
Power Source 2 × AAA Batteries
Protection Class IP65
Temperature Compensation None
Dimensions / Weight 5.5×3.1×10.9 cm, 100g

Applications

  • SrCl₂ concentration control in ceramic and glass manufacturing
  • Quality control in specialty chemical production processes
  • Rapid SrCl₂ measurement under field conditions

Frequently Asked Questions

Does the PAL-48S have temperature compensation?
No, the device does not feature automatic temperature compensation; measurements should be performed within the 10-40°C operating range.
How much sample is required for measurement?
Only 2-3 drops of sample are needed, with results obtained in approximately 3 seconds.
Can the device be used in demanding environments?
Yes, the IP65 protection rating allows it to be used in manufacturing environments containing water and dust.