Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-56S Potassium Sulfate Refractometer

Fiyat Sorunuz

Digital handheld refractometer for fast measurement of concentration and temperature in potassium sulfate (K₂SO₄) solutions. Designed for quality control in fertilizer, agricultural, and chemical industries. Delivers results in 3 seconds with just 2-3 drops of sample.

  • Measurement range: K₂SO₄ 0.0-15.0% (g/100g)
  • Accuracy: ±0.3% K₂SO₄, ±1°C temperature
  • Resolution: 0.1% K₂SO₄, 0.1°C temperature
  • Measurement time ~3 seconds, sample volume 2-3 drops
  • IP65 water resistance, portable operation with 2×AAA batteries
  • No temperature compensation—use within operating range (10-40°C)

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-56S is a digital handheld refractometer manufactured by Atago and specifically calibrated to measure the concentration and temperature of potassium sulfate (K₂SO₄) aqueous solutions. It is used for concentration monitoring in fertilizer production, agricultural application control, and related chemical processes.

The instrument performs measurements across the 0.0-15.0% K₂SO₄ range with ±0.3% accuracy, requiring only 2-3 drops of sample and approximately 3 seconds measurement time. Thanks to its IP65 water resistance rating, it can be safely used in both field and laboratory environments. Its compact size (5.5×3.1×10.9 cm, 100g) and AAA battery operation enhance portability.

Note: The instrument does not feature automatic temperature compensation, therefore measurements must be performed within the specified 10-40°C operating temperature range, and results should be evaluated accordingly.

Technical Specifications

Model PAL-56S
Manufacturer Atago
Measurement Range K₂SO₄: 0.0-15.0% (g/100g); Temperature: 10.0-40.0°C
Resolution 0.1% K₂SO₄ / 0.1°C temperature
Accuracy ±0.3% K₂SO₄, ±1°C temperature
Operating Temperature 10-40°C ambient
Measurement Time ~3 seconds
Sample Volume 2-3 drops
Power Supply 2 × AAA batteries
Protection Rating IP65
Dimensions / Weight 5.5×3.1×10.9 cm, 100g
Temperature Compensation None

Applications

  • K₂SO₄ concentration control in fertilizer production
  • Concentration verification in agricultural solution preparation
  • Potassium sulfate solution monitoring in chemical processes

Frequently Asked Questions

What concentration range does the PAL-56S measure?
It measures across the 0.0-15.0% K₂SO₄ (g/100g) range with ±0.3% accuracy.
Does the instrument have automatic temperature compensation?
No, it does not feature temperature compensation. Measurements must be performed within the 10-40°C operating temperature range.
How much sample is required for measurement?
Only 2-3 drops of sample are needed, with results obtained in approximately 3 seconds.