Novatek Analytic Ethylene Oxide Residue Gas Chromatography (Face Mask Testing)

Fiyat Sorunuz

Gas chromatography with FID detector precisely and repeatably measures ethylene oxide (EO) sterilization residues in face masks and medical materials. Delivers automated analysis with headspace sampler.

  • FID (Flame Ionization Detector), optional alternative detector configurations
  • Detection limit ≤3×10⁻¹²g/s (n-hexadecane)
  • Specialized 30m×0.32mm×0.5µm column for ethylene oxide analysis
  • 20-position automated headspace sampler
  • Temperature range 4℃-450℃, control accuracy ±0.1℃
  • 16-step programmed heating, six-zone temperature control

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

This gas chromatography system is designed to detect ethylene oxide (EO) sterilization residues in products such as face masks, medical devices, and sterile packaging. The hydrogen flame ionization detector (FID) measures organic volatile compounds with high sensitivity and can optionally be equipped with alternative detector types.

The instrument is configured with a 30m×0.32mm×0.5µm chromatographic column specifically selected for ethylene oxide analysis and a 20-position headspace autosampler, which automates the sample preparation and analysis workflow. The temperature control system features six-zone regulation operating between 4℃ and 450℃ with ±0.1℃ accuracy, enabling creation of 16-step programmed heating profiles.

Detector performance specifications include: ≤3×10⁻¹²g/s (n-hexadecane) detection limit, ≤2×10⁻¹⁴A baseline noise, and ≤1×10⁻¹³A/30min baseline drift, ensuring reliable detection of low-level EO residues. Real-time temperature and chromatogram monitoring via LCD display; professional software generates PDF analytical reports.

Suitable for petrochemical, pharmaceutical, medical device manufacturing, commodity inspection, and environmental analysis laboratories determining ethylene oxide and other organic solvent residues.

Technical Specifications

Detector Flame Ionization Detector (FID), optional alternative detectors
Detection Limit ≤3×10⁻¹²g/s (n-hexadecane)
Baseline Noise ≤2×10⁻¹⁴A
Baseline Drift ≤1×10⁻¹³A / 30 min
Chromatographic Column Ethylene oxide analysis column 30m × 0.32mm × 0.5µm (optional)
Headspace Sampler Capacity 20 positions
Detector Dimensions 240 × 210 × 240 mm
Temperature Range Ambient +4℃ to 450℃ (1℃ increments)
Temperature Control Accuracy ±0.1℃
Temperature Gradient ±1%
Temperature Control Method Six-zone control, 16-step programming, 0.1-60℃/min ramp rate
Standard Ethylene Oxide Standard

Applications

  • EO sterilization residue testing in face masks and medical devices
  • Organic solvent residue analysis in sterile packaging materials
  • Pharmaceutical and healthcare product quality control
  • Commodity inspection and environmental analysis laboratories

Frequently Asked Questions

Does this instrument measure only ethylene oxide?
While EO residue testing is its primary application, the FID detector enables detection and purity analysis of other organic solvents as well.
Why is the headspace sampler important?
The 20-position headspace autosampler automates sample preparation, providing consistent and rapid analysis capability.
How flexible is the temperature programming?
With six-zone temperature control, up to 16 programmed heating steps can be configured, with ramp rates adjustable between 0.1-60℃/min.