Stoklu siparişleriniz aynı gün kargoda!

MycoSep® and MultiSep® Sample Cleanup Columns

Fiyat Sorunuz

Specialized mycotoxin purification columns for food and feed analysis — single-stage cleanup in 30 seconds

  • 30-second single-stage sample cleanup
  • Comprehensive mycotoxin-specific sorbent formulations
  • Remove interferences while retaining target analytes
  • Proven for aflatoxins, trichothecenes, ergot alkaloids, ochratoxins, and more
  • Available in MycoSep® push-tube and MultiSep® column formats

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

MycoSep® and MultiSep® columns contain concentrated sorbent material mixtures specifically engineered for all food and feed products. These single-stage cleanup columns deliver purified extracts in 30 seconds, removing interferences while preserving target analytes for accurate mycotoxin analysis.

Technical Specifications

Part Number COCMY2112, COCMY2113, COCYM2150, COCYM2224, COCMY2225, COCMY2226, COCMY2227, COCMY2228, COCMY2229, COCMY2230, COCMY2231, COCMY2240
Cleanup Time 30 seconds
Method Format Single-stage cleanup

Applications

  • Aflatoxin and zearalenone detection in grains and feeds
  • Trichothecene analysis in cereals
  • Ergot alkaloid screening in grain samples
  • Patulin quantitation in fruit-based foods
  • Ochratoxin A determination in coffee and nuts
  • Nivalenol and fumonisin analysis
  • Moniliformin detection in animal feed
  • Pre-analytical sample purification for LC-MS/MS and HPLC

Frequently Asked Questions

What is the difference between MycoSep® and MultiSep® columns?
MycoSep® columns use a push-tube format where sample extract is forced upward through the concentrated sorbent material within the column body. MultiSep® columns employ a gravity-flow format where sample extract is applied to the top and flows downward through the sorbent. Both achieve single-stage cleanup in 30 seconds.
How does the cleanup process work?
Interferences bind irreversibly to the chemical sorbent phase, while purified extract containing target analytes passes through or is collected. This selective separation occurs in a single 30-second step.
Are these columns compatible with my HPLC or LC-MS/MS system?
Yes. MycoSep® and MultiSep® columns produce extracts suitable for direct injection into HPLC, LC-MS/MS, and other chromatographic methods without additional filtration steps.