Stoklu siparişleriniz aynı gün kargoda!

Laminar Flow Cabin Class 2 Mikrotest MLF – Biosafety Cabinet

Fiyat Sorunuz

Class II biosafety cabinet providing superior protection for user, environment, and product during microbiological work with harmful or uncertain-risk microorganisms.

This product is currently out of stock and unavailable.

  • Class II biosafety cabinet with ISO 5 (Class 100) workspace cleanliness
  • Dual H14 HEPA filters achieving 99.995% filtration efficiency at 0.3 µm particles (EN 1822)
  • H14-grade aluminum housing with reinforced construction
  • Laminar airflow protection against cross-contamination
  • Multiple model sizes: MLF-90, MLF-120, MLF-150, MLF-180
  • Low-noise operation: <58 dB(A) in normal mode, <52 dB(A) in economy mode
  • Adjustable front sash with standard (200 mm) and maximum (530 mm) opening heights
  • 316 stainless steel work surface (standard)
  • Continuous-lubricated centrifugal fan technology
  • Voltage-stable, energy-efficient motor design

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Laminar Flow Cabin Class 2 Mikrotest MLF is a Class II biosafety cabinet engineered for comprehensive safety in microbiological laboratories. Designed for all operations involving potentially hazardous microorganisms with uncertain or known risk levels, the MLF Series cabinets deliver multi-level protection through advanced HEPA filtration and laminar airflow technology. The workspace is protected against particulates generated during procedures, while ambient airborne contaminants are completely excluded. Cross-contamination protection is ensured for the operator, work environment, and processed materials. The cabinet features H14-grade aluminum construction with dual-surface protective H14 HEPA filters; wood or fiberboard materials are strictly excluded from the filter assembly. Cabinets are dynamically balanced on dual planes with continuous-lubricated centrifugal fans or direct-drive motors, providing low noise, minimal vibration, and extended service life. Energy-efficient next-generation fans maintain stable airflow despite building voltage fluctuations, meeting all relevant standards for biosafety laboratory use.

Technical Specifications

Product Category Class II Biosafety Cabinet
Available Models MLF-90, MLF-120, MLF-150, MLF-180
Internal Dimensions MLF-90 (W×D×H) mm 90×63×65
Internal Dimensions MLF-120 (W×D×H) mm 120×63×65
Internal Dimensions MLF-150 (W×D×H) mm 150×63×65
Internal Dimensions MLF-180 (W×D×H) mm 180×63×65
External Dimensions MLF-90 (W×D×H) mm 106.5×90×145
External Dimensions MLF-120 (W×D×H) mm 136×90×145
External Dimensions MLF-150 (W×D×H) mm 166×90×145
External Dimensions MLF-180 (W×D×H) mm 196×90×145
Stand Dimensions MLF-90 (W×D×H) mm 1060×870×750
Stand Dimensions MLF-120 (W×D×H) mm 1360×870×750
Stand Dimensions MLF-150 (W×D×H) mm 1660×870×750
Stand Dimensions MLF-180 (W×D×H) mm 1960×870×750
Work Surface Height from Floor 850 mm
Inflow Air Velocity (adjustable range) 0.25 – 0.50 m/s
Primary Filter Type (EN 1822) H14 HEPA, 99.995% efficiency at 0.3 µm particles
Exhaust Filter Type (EN 1822) H14 HEPA, 99.995% efficiency at 0.3 µm particles
Pre-Filter Type (EN 1822) G4
Workspace Cleanliness Class (US FED 209E) ISO 5 – Class 100
Ducting Capacity Suitable for 10 m horizontal and 3 m vertical duct runs
Work Surface Material (Standard) 316 Stainless Steel
Front Sash Opening (Standard Preset) 200 mm ± 10 mm
Front Sash Opening (Maximum Height) 530 mm ± 10 mm
Noise Level (Normal Mode) MLF-90 <58 dB(A)
Noise Level (Normal Mode) MLF-120 <58 dB(A)
Noise Level (Normal Mode) MLF-150 63 dB(A)
Noise Level (Normal Mode) MLF-180 63 dB(A)
Noise Level (Economy Mode) MLF-90 <52 dB(A)
Noise Level (Economy Mode) MLF-120 <52 dB(A)

Applications

  • Microbiological cultivation and analysis work
  • Handling pathogenic and risk-group microorganisms
  • Pharmaceutical and biotech research operations
  • Clinical microbiology laboratory procedures
  • Vaccine and immunological research
  • Environmental and water quality microbiology testing
  • Diagnostic microbiology procedures
  • Sterile pharmaceutical compounding
  • Cell culture and tissue engineering work
  • Food and beverage safety testing

Frequently Asked Questions

What biosafety level is the MLF cabinet classified as?
The Laminar Flow Cabin Class 2 Mikrotest MLF is a Class II biosafety cabinet, suitable for work with pathogenic and uncertain-risk microorganisms, providing protection to the operator, environment, and product through HEPA filtration and laminar airflow technology.
What is the filtration efficiency of the HEPA filters?
Both primary and exhaust filters are H14-grade HEPA filters (EN 1822 standard) with 99.995% filtration efficiency for particles at 0.3 micrometers, ensuring maximum contamination control.
What models are available and how do they differ?
Four models are offered: MLF-90, MLF-120, MLF-150, and MLF-180, differentiated by workspace width (90, 120, 150, and 180 mm respectively). All models maintain identical depth (63 mm), height (65 mm), and performance specifications.
What is the workspace cleanliness classification?
The workspace achieves ISO 5 (Class 100) cleanliness classification per US FED 209E standards, suitable for microbiological and pharmaceutical applications.
Can the front sash opening be adjusted?
Yes. The cabinet offers a standard preset opening of 200 mm ± 10 mm and a maximum opening height of 530 mm ± 10 mm, allowing flexibility for different procedures and equipment.
What materials are used in construction?
The cabinet features H14-grade aluminum housing with 316 stainless steel work surface. All filter assemblies use only metal and synthetic materials; wood and fiberboard are strictly excluded.
How is airflow stability maintained?
The cabinet employs energy-efficient next-generation fans with electronic voltage regulation, ensuring stable airflow despite building power fluctuations, with adjustable velocity from 0.25 to 0.50 m/s.
What noise levels can be expected?
Normal operating mode produces <58-63 dB(A) depending on model (MLF-90/120: <58 dB, MLF-150/180: 63 dB). Economy mode operation is quieter at <52 dB(A) for smaller models [to be verified for larger models].
What ductwork requirements must be met?
The exhaust fan motor is rated for duct systems up to 10 meters in horizontal length and 3 meters in vertical height, with standard ducting requirements.
Is installation on a stand required?
While not mandatory, stands are available for each model size, positioning the work surface at the ergonomic height of 850 mm. Specifications for stands are provided for planning workspace layout.