Deionized Water System Chemetrics

Fiyat Sorunuz

High-purity deionized water generation system producing Type I and Type III ultrapure water for laboratory applications

  • Dual output system: Type III and Type I deionized water production
  • Advanced reverse osmosis membrane with automated cleaning function
  • Microprocessor-controlled operation with touchscreen interface
  • Real-time water conductivity monitoring via digital display
  • Automatic water cycling system for maintained water quality
  • 128 x 64 large LCD display with operational parameter readout
  • Automatic system diagnostics on startup with water/power failure alarm
  • Consumable replacement monitoring and notification system

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The Chemetrics Deionized Water System is a microprocessor-controlled purification device designed for laboratory applications requiring high-quality deionized water. It produces Type III grade water (0-10 µs/cm) from Output 1 and Type I grade water (0.056 µs/cm, 18.25 MΩ.cm at 25°C) from Output 2, meeting stringent purity standards for analytical and biological research.

Technical Specifications

Type I Output Conductivity 0.056 µs/cm (18.25 MΩ.cm at 25°C)
Type III Output Conductivity 0-10 µs/cm
Inlet Water Requirement Tap water
Inlet Water Pressure 1.0-5.0 kg/cm²
Reverse Osmosis Membrane Capacity 5-100 lt/hour
Pure Water Flow Rate 1.5 lt/minute
Silica Removal Rate Si > 99.9%
Absorbance (254 nm, 1 cm path) ≤ 0.001
Dissolved Silicon (SiO₂) < 0.01 ppm
Particulate Matter (>0.22 µm) < 1/ml
Heavy Metal Content (ppm, max) < 0.001
Total Organic Carbon (TOC) < 6 ppb
Microbial Load (CFU/ml) < 1 cfu/ml (254 nm)
Pyrogens (Endotoxin) < 0.005 EU/ml
Membrane Filtration 0.22 µm
UV Sterilization Wavelength 254 nm
Power Supply 220V / 50 Hz
Voltage Fluctuation Tolerance ± 10%
Operating Temperature Range 5-40°C
Dimensions 460 × 480 × 500 mm

Applications

  • Bacterial and mammalian cell culture
  • Plant tissue culture and micropropagation
  • HPLC analysis (amino acids, penicillin assays, organic compound testing)
  • General immunological applications
  • Microbiological and microbial testing
  • Protein purification protocols
  • Protein analysis and characterization studies
  • Buffer solution and high-purity reagent preparation
  • Total Organic Carbon (TOC) analysis
  • Toxicity testing and environmental screening
  • Chromatography and analytical chemistry

Frequently Asked Questions

What is the difference between Type I and Type III water?
Type I water (18.25 MΩ.cm) is the highest purity grade, suitable for analytical HPLC, chromatography, and sensitive biological assays. Type III water (0-10 µs/cm) is suitable for general laboratory use, media preparation, and rinsing. This system produces both grades from separate outputs.
What is the water production capacity?
The reverse osmosis membrane capacity is 5-100 lt/hour, with a pure water flow rate of 1.5 lt/minute from the main output.
Does the system include UV sterilization?
Yes, the system features a 254 nm UV sterilization lamp to reduce microbial contamination to <1 cfu/ml, meeting requirements for sensitive applications.
What happens during water or power interruptions?
The system includes automatic alarm notifications for both water supply failures and power interruptions, protecting your applications from unexpected water quality changes.
How is water quality maintained during storage?
The microprocessor-controlled automatic water cycling system activates at timed intervals to circulate stored water, maintaining Type I water quality standards throughout the reservoir.
What maintenance is required?
The system monitors consumable filter cartridges and alerts users when replacement is needed. Reverse osmosis membrane cleaning is controlled via dedicated touchscreen button.
What inlet water quality is required?
Standard tap water is the inlet source. The system can accept tap water with inlet pressure of 1.0-5.0 kg/cm² for optimal RO membrane performance.