Stoklu siparişleriniz aynı gün kargoda!

Atago PAL-41S Calcium Chloride Refractometer

Fiyat Sorunuz

Digital handheld refractometer measuring calcium chloride (CaCl2) aqueous solution concentration in 3 seconds. Designed for de-icing agent control and industrial process monitoring.

  • 0.0–35.0% measurement range with calcium chloride-specific calibration
  • ±0.2% accuracy, 0.1 Brix resolution
  • 3-second results with only 2–3 sample drops
  • 10°C–40°C automatic temperature compensation
  • IP65 dust and water protection
  • 2×AAA battery-powered portable operation

Kargolama ve Teslimat

  • Kurye Teslimatı

Kuryemiz belirtilen adrese teslimat yapacaktır.

2-3 Gün

Ü.A. Kargo

  • Aras Kargo Teslimatı

Aras Kargo kuryesi belirtilen adrese teslimat yapacaktır.

1-3 Gün

Ücretsiz Kargo

  • Garanti 2 yıl
  • 14 Günlük ücretsiz iade

The PAL-41S is a digital handheld refractometer specifically calibrated to measure calcium chloride aqueous solution concentration in g/100g units. Manufactured by Atago, it delivers results in just 3 seconds using only 2–3 sample drops.

With a 0.0–35.0% measurement range and ±0.2% accuracy, it provides reliable results for de-icing solution preparation, industrial process control, and quality assurance applications. Automatic temperature compensation between 10°C–40°C ensures consistent measurements in both field and laboratory environments. IP65 protection rating shields the unit against dust and water exposure, making it particularly practical for field deployment. Battery-powered operation (2×AAA) ensures portability.

Ideal for de-icing agent manufacturers, municipal winter road maintenance crews, and chemical solution production facilities seeking a practical on-site measurement solution.

Technical Specifications

Manufacturer Atago
Model PAL-41S
Catalog No. 4441
Measurement Scale Calcium Chloride (g/100g)
Measurement Range 0.0 – 35.0%
Resolution 0.1 Brix
Accuracy ±0.2%
Temperature Compensation 10°C – 40°C
Sample Volume 2-3 drops
Measurement Time 3 seconds
Power Source 2 × AAA Battery
Protection Rating IP65

Applications

  • Calcium chloride (de-icing) solution concentration control
  • Chemical process and quality control laboratories
  • On-site rapid concentration measurement

Frequently Asked Questions

What substance does the PAL-41S measure?
The unit is specifically calibrated to measure calcium chloride aqueous solution concentration in g/100g units.
Does it have temperature compensation?
Yes, automatic temperature compensation is included for the 10°C–40°C range, requiring no additional corrections.
Can it be used in the field?
Yes, IP65 protection rating and battery operation make it fully suitable for field conditions.